Alpha Alpha CD Easy-Flue Installation Instructions Download Page 1

Installation Instructions

KIT CONTENTS

1.

GENERAL

Note: These flues MUST ONLY be used with the Alpha CD Condensing boilers.

a.

The Alpha Easy-Flue is suitable for straight horizontal flues only and can be extended up to the maximum lengths
given in paragraph (f), below.

b.

The easy-Flue includes a 90° bend, (no separate 90° bend is required).

c.

Ensure the flue assembly is installed horizontally and the inner flue duct has a slight downward slope towards the boiler.

d.

The flue system must be installed in accordance with BS 5440:1:1990.

e.

The boiler must be installed in accordance with the installation instructions supplied with the CD boiler.

f.

The CD Easy-Flues are suitable for use in the flue length ranges shown in the tables below.

Note: Where the length is less than the minimum or more than the maximum, refer to section 4.

Alpha CD Easy-Flue

CD Easy-Flue 500 mm Part No. 6.2000500
CD Easy-Flue 1000 mm Part No. 6.2001000

Fig. 1

Fig. 2

CD Easy-Flue

500 mm

1000 mm

B (mm)

Max

520

915

Min

280

675

CD Easy-Flue

500 mm

1000 mm

Max

460

855

Min

220

615

B + C (mm)

Reviews: