Assigning a remote to a motor (You have 10 seconds to complete the task)
Technical Speci
fi
cations
Power AC 120v/60Hz
Loaded Power 400w
Protection Index: IP 44
Up to 15 remotes (or channels) may be assigned to each motor
Thermal protection will engage after 4 minutes of continuous running
Wire Connections
Assigning an extra remote (or channel) to a motor via the original remote
Deleting a remote (or channel) from a motor (You have 10 seconds to complete the task)
WSER Universal Motors Page 4.
WSER Universal Motors Page 1.
Press the UP and DOWN
buttons simultaneously,
then release.
Press the UP and DOWN
buttons simultaneously,
then release.
You can now use the new
remote to control the motor.
Press the STOP button
8 times, the motor will
vibrate.
Press the STOP button
once, the motor will
vibrate.
Method A.
Only works for the
fi
rst
remote assigned to the motor.
Press the UP and DOWN
buttons simultaneously, then
release.
Press the STOP button 7 times.
Press the UP button once, the
motor will vibrate
This remote (or channel) has now
been deleted from the motor.
Method A.
This will delete the individual remote (or channel) you are currently using
1. The RE101 remote has been used as an example here in diagrams. All Alpha remotes are compatible
with these motors.
2. Strong local RF levels from other equipment may affect some setup functions. If a step fails, simply
repeat the process.
3. Be careful not to speed through the setup process until you are 100% sure of what you are doing.
4. These motors and accessories are not toys, do not allow children to play with them.
5. Ambient operating temperature is: -10 C - +55 C
6. All Alpha products may be subject to change without notice.
You can now use the remote
to control the motor.
Press the UP and DOWN buttons
simultaneously, then release.
Turn power on, the motor
will vibrate
Press the STOP button once,
the motor will vibrate.
Method B.
Can be used at any time.
Method A
.
can only be used again if you cut and restore power to the motor 3 times. You must allow 5 seconds before restoring
power each time and you must allow the motor to vibrate properly each time. After the third cycle, you may assign the remote.
Press the STOP button once, the
motor will vibrate.
Press the UP and DOWN buttons
simultaneously, then release.
You can now use the remote to
control the motor.
Press the red button on the motor
for 1 second
06.04.SMS-ERJB-8479-V2
Handy Tips
1. If this motor is used on an awning and works with the Alpha RS001wind-light
sensor or RS005 motion sensor, there is constant radio communication between the
motor and sensor. If the motor doesn't receive radio communication from the sensor
for 35 minutes after opening, the motor will automatically close the awning as a
protective measure. This indicates that there is either a problem that needs investigat
-ion, or in the case of the motion sensor that the batteries might need changing.
2. Always roll the blind down and up before setting the top limit. Failure to do so
may result in a change of limit position due to a change in blind tension. Simply
setting the bottom limit first will prevent this happening.
3. When pressing up and down simultaniously during setup, be as precise as
possible. Ideally it should sound like one button click when both are pressed.
4. If you catch yourself making an error during a setup process, stop and allow 10
seconds for the motor to time out, then try again.
5. Do not hold any buttons down during setup process unless specifically told to do
so. A half second press should be plenty and allow 1 second between presses.
6. If you are using a multi-channel remote, make certain that it is on the correct
channel before you assign it to a motor. This is a common mistake.
ER Motors Instruction
ER Motors Instruction
up
stop
down
antenna
neutral wire (white
)
ground wire
(
green
)
live wire (black)
AC Power
120V
purple
blue
up
stop
down
antenna
neutral wire (white
)
ground wire
(
green
)
live wire (black)
AC Power
120V
AC Power
1
2
3
4
5
1
1
1
1
1
1
1
1
1
1
1
1
7
8
1
1
1
Original
Original
NEW
NEW
!
Announcement
04
01
Single-Control Switch(be compatible with 5-core wires ER tubular motor)
B If you want to use the motor with Single-Control switch, please connect motor and switch as per below indication firstly.
Then use an assigned remote to do following steps:
---Short press emitter’s UP&DOWN button simultaneously and release.
---Short press emitter’s
STOP
button 7 times
;
---Short press DOWN button one time and release, the
motor jiggles.
Now
you can use the Single-Control switch to control the tubular motor properly.
The tubular motor will run Up - Stop- Down - Stop-Up-Stop cycle when
the switch is pressed each time.