Alpha Motors WSER50 Series Quick Start Manual Download Page 1

Assigning a remote to a motor (You have 10 seconds to complete the task)

Technical Speci

 cations 

Power AC 120v/60Hz

Loaded Power 400w

Protection Index: IP 44

Up to 15 remotes (or channels) may be assigned to each motor
Thermal protection will engage after 4 minutes of continuous running

Wire Connections

Assigning an extra remote (or channel) to a motor via the original remote 

Deleting a remote (or channel) from a motor (You have 10 seconds to complete the task)

WSER Universal Motors    Page 4.

WSER Universal Motors    Page 1. 

Press the UP and DOWN

buttons simultaneously, 

then release. 

Press the UP and DOWN

buttons simultaneously, 

then release. 

You can now use the new

remote to control the motor.

Press the STOP button

8 times, the motor will

vibrate.  

Press the STOP button

once, the motor will 

vibrate. 

Method A.

Only works for the 

 rst 

remote assigned to the motor.

Press the UP and DOWN 

buttons simultaneously, then 

release.

Press the STOP button 7 times.

Press the UP button once, the 

motor will vibrate

This remote (or channel) has now 

been deleted from the motor.

Method A.

This will delete the individual remote (or channel) you are currently using

1. The RE101 remote has been used as an example here in diagrams. All Alpha remotes are compatible

with these motors. 
2. Strong local RF levels from other equipment may affect some setup functions. If a step fails, simply

repeat the process.
3. Be careful not to speed through the setup process until you are 100% sure of what you are doing.
4. These motors and accessories are not toys, do not allow children to play with them.
5. Ambient operating temperature is: -10 C - +55 C
6. All Alpha products may be subject to change without notice.

You can now use the remote 

to control the motor. 

Press the UP and DOWN buttons

simultaneously, then release. 

Turn power on, the motor

will vibrate 

Press the STOP button once, 

the motor will vibrate. 

Method B.

Can be used at any time.

Method A

can only be used again if you cut and restore power to the motor 3 times. You must allow 5 seconds before restoring 

power each time and you must allow the motor to vibrate properly each time. After the third cycle, you may assign the remote. 

Press the STOP button once, the 

motor will vibrate.

Press the UP and DOWN buttons 

simultaneously, then release.

You can now use the remote to 

control the motor.

Press the red button on the motor 

for 1 second

06.04.SMS-ERJB-8479-V2

Handy Tips

1. If this motor is used on an awning and works with the Alpha RS001wind-light

sensor or RS005 motion sensor, there is constant radio communication between the

motor and sensor. If the motor doesn't receive radio communication from the sensor 

for 35 minutes after opening, the motor will automatically close the awning as a

protective measure. This indicates that there is either a problem that needs investigat

-ion, or in the case of the motion sensor that the batteries might need changing. 

2. Always roll the blind down and up before setting the top limit. Failure to do so

may result in a change of limit position due to a change in blind tension. Simply

setting the bottom limit first will prevent this happening. 

3. When pressing up and down simultaniously during setup, be as precise as

possible. Ideally it should sound like one button click when both are pressed. 

4. If you catch yourself making an error during a setup process, stop and allow 10

seconds for the motor to time out, then try again. 

5. Do not hold any buttons down during setup process unless specifically told to do

so. A half second press should be plenty and allow 1 second between presses.

6. If you are using a multi-channel remote, make certain that it is on the correct

channel before you assign it to a motor. This is a common mistake.

ER Motors Instruction

ER Motors Instruction

up

stop

down

antenna

neutral wire  (white

 ground wire

green

  live wire (black) 

AC Power

120V

purple        

  

blue

up

stop

down

antenna

neutral wire  (white

 ground wire

green

  live wire (black) 

AC Power

120V

AC Power

1

2

3

4

5

1

1

1

1

1

1

1

1

1

1

1

1

7

8

1

1

1

Original

Original

NEW

NEW

Announcement

04

01

Single-Control Switch(be compatible with 5-core wires ER tubular motor)

B  If you want to use the motor with Single-Control switch, please connect motor and switch as per below indication firstly. 

  

Then use an assigned remote to do following steps: 

  

---Short press emitter’s UP&DOWN button simultaneously and release.

 

  

  

---Short press emitter’s 

STOP 

button 7 times

  

---Short press DOWN button one time and release, the 

motor jiggles.

  Now

 you can use the Single-Control switch to control the tubular motor properly.

 The tubular motor will run Up - Stop- Down - Stop-Up-Stop cycle when 

  the switch is pressed each time.              