background image

mm

(inch)

Dimensions (E3060)

- 10 -

Summary of Contents for E Series

Page 1: ...BASE SOFT LIGHT E SERIES USER MANUAL July 2019 ...

Page 2: ......

Page 3: ... as safety helmet during work 3 Be sure to fix the safety chain on the product when installing and moving 4 Please install the signs below for people to bypass when install the product on high truss 5 The work should be done under the direction of approved specialist who is trained in safety and mechanical installations WARNING 3 ...

Page 4: ...struction Unlocking 16 Main Screen Instruction 17 Setting Screen Instruction 17 Setting Mode Change 18 Channel Mode Change 18 DMX512 Address Setup 20 Brightness Intensity Adjust 21 CCT Adjust Correlated Color Temperature 21 Fixture ID Setup and Change 22 LCD Off Setup 23 LCD Rotation Setup 23 RDM Setup 24 Dimming Speed Setup 24 Master Setup 25 Wireless Setup 25 Error Information Temperature Sensor...

Page 5: ...iffusivity low in glare and not exposed to elements The LED lighting source sets on the side edge with reflection and pattern optical technology applied It is the best base light to emit an extremely soft light source without glare 2 900 6 000K color temperature control function and average 97 or more high CRI LED light source 5 ...

Page 6: ...Fixture Exterior View Stirrup Smart Touch LCD Screen Handle Connector Panel Fixed Knob 6 ...

Page 7: ...mm inch Dimensions E1360 7 ...

Page 8: ...mm inch Dimensions E2040 8 ...

Page 9: ...mm inch Dimensions E2440 9 ...

Page 10: ...mm inch Dimensions E3060 10 ...

Page 11: ... Stirrup High Strength Tilt Lock Mounting 16mm 28mm Tilt Angle 270 Power Supply Range AC 100 240V 50 60Hz Power Consumption 150W 150W 200W 300W White Light CCT Full 2 900 6 000K VCT CRI 95 98 Dimming 0 100 16 bit Control 5 PIN DMX In and Out Smart Touch LCD Controller RDM Option Wireless DMX512 Wireless RDM Remote Device Management Supported Ambient Temperature Operation 20 45 C IP Rating IP20 Est...

Page 12: ...Photometric Diagram 12 E1360 E2040 E2440 E3060 343 277 349 548 141 123 148 225 77 69 82 122 45 41 50 76 9 ...

Page 13: ...Light Reflection Sheet LGP Lamp Reflector Ad Film Reflection Sheet LGP Side Reflection System 13 ...

Page 14: ... SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged Power Connection AC power at 100 240V 50 60Hz 14 1 POWER ON OFF SWITCH 2 POWER IN 3 POWER OUT 4 DMX IN 5 DMX OUT 6 USB PORT for ADMINISTRATOR ONLY Do not connect USB without administrator s permission ...

Page 15: ...e for connect the DMX controller to other XLR output 1 Shield 2 Signal 3 Signal 4 Not Connected 5 Not Connected Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture and connect one output to the input of the next fixture until all fixtures are connected In the last lighting fixture the DMX cable must be end with a terminator 120 Ω resistor in DMX o...

Page 16: ...imes If you do not touch for 30 seconds the lock is reset If the power is turned off and then on again while the fixture ID number screen is displayed the fixture ID lock screen will appear To unlock the touch screen touch the exit icon to move to Main Screen Locked and press the finger icon three times If you do not touch for 30 seconds the lock is reset A B A Unlocking 16 ...

Page 17: ... The current channel mode is displayed 9 Fixture ID Displays numbers for equipment management 10 Fixture Current Temperature The current temperature of the instrument is detected and displayed in C 11 Equipment Information You can see basic information about the equipment 12 Brightness Setup Set lighting brightness 13 CCT Setup Set correlated color temperatre 14 DMX512 Address Setup Set channel mo...

Page 18: ...ipulates the equipment It is used for maintenance DMX Mode User Mode User Mode DMX Mode When in DMX mode user can change to user mode by adjusting the brightness in Setting Brightness When in User mode user can change to DMX mode through the Setting DMX512 Channel selection DMX address Setting Mode Change 18 ...

Page 19: ... by selecting Current channel mode in main screen or DMX512 Channel selection DMX address in setting Pressing the icon in Channel Mode displays information for each channel OR 1 1 Ch mode Dimming 2 2 Ch mode Dimming CCT Setting Channel Mode Change 19 ...

Page 20: ...the value can changed by RDM The number blinks when the connection is disconnected Touch DMX512 Setup Channel Mode on the Setting screen to switch to the input window 001 512 value can be entered Press icon to save the DMX512 adress and move to the main screen Also the value can changed by RDM The number blinks when the connection is disconnected DMX512 Address Setup in Setting Setting DMX512 Addr...

Page 21: ...elated Color Temperature Adjust The number indicates the current color temperature value of the fixture and is displayed from 2 900 to 6 000K Touch CCT on the main screen or the setting screen to adjsut the color temperature value Touch the gradient bar to apply it close to the desired value and then touch to set the correct value OR In 1 channel mode user can set the desired color temperature by ...

Page 22: ...the model name and can be changed through RDM communication but it can not be changed through Smart Touch LCD When changing the name of the device through RDM enter the device name English and the management number in the Device Label field The entered contents are displayed in the upper left corner The fixture ID is automatically displayed in 3 digits from automatically recognized 3 digits in con...

Page 23: ...D Off Enable The screen automatically turns off after 30 seconds if there is no touch operation LCD Off Disable The screen stays on all the time Default LCD Rotation Setup Each time touch on the main screen the screen rotates 180 It is used to change the direction of the LCD screen according to the installation direction of the fixture 23 ...

Page 24: ... to adjsut the dimming speed value 0 40 can be set by touching the arrows The larger the number the slower the dimming speed Touch RDM Setup on the setting screen to display the above selection screen RDM Enable Enable RDM communication function RDM Disable Disables RDM communication function Default 24 ...

Page 25: ...e only upon order Touch Wireless Setup on the setting screen to display the left selection screen Wireless Enable Enable wireless DMX512 mode Wireless Disable Enable DMX512 mode or disable wireless DMX512 mode Default Unlink Wireless Unlink or disconnect the wireless module Master Setting Precautions 1 Remove the DMX IN connection 2 In the same network set only one equipment to master 3 Set all eq...

Page 26: ... actual LED output will be 60 If it exceeds 85 C the actual LED output will be 0 The error messages are only displayed on the main screen and the fixture ID screen and even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Temperature Sensor When the DMX512 network connection is lost the DMX512 address number i...

Page 27: ...50K 176 179 5100K 180 183 5150K 184 187 5200K 188 191 5250K 192 195 5300K 196 199 5350K 200 203 5400K 204 207 5450K 208 211 5500K 212 215 5550K 216 219 5600K 220 223 5650K 224 227 5700K 228 231 5750K 232 235 5800K 236 239 5850K 240 243 5900K 244 247 5950K 248 255 6000K MODE 2 DMX Value Function CHANNEL 2 76 79 3850K 80 83 3900K 84 87 3950K 88 91 4000K 92 95 4050K 96 99 4100K 100 103 4150K 104 107 ...

Page 28: ...S YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Lamp Controls No Control Property Value Example Description User Settings Remarks 1 Identify On N A Device identification action active Enable Identify device Same as On 2 Identify Off N A Device identification action inactive Enable Identify device Same as Off 3 Cold Reset N A ...

Page 29: ... Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only no actual response 10 Lamp On Mode N A N A Display only no actual response 11 Display Invert On LCD screen display direction Enable Off 0 On 180 Auto Current opposite direction 12 Identify Device Off Selected f...

Page 30: ...lue Description 2 Ch Model Device Variable Color Temperature 1 Ch Mode 1 Ch Mode 2 Ch Mode 2 Ch Mode 1 Ch 2900K 1 Ch Mode 2900K Color Temperature 1 Ch 3000K 1 Ch Mode 3000K Color Temperature 1 Ch 3100K 1 Ch Mode 3100K Color Temperature 1 Ch 3200K 1 Ch Mode 3200K Color Temperature 1 Ch 4400K 1 Ch Mode 4400K Color Temperature 1 Ch 4500K 1 Ch Mode 4500K Color Temperature 1 Ch 5500K 1 Ch Mode 5500K Co...

Page 31: ... information and questions please visit our website or call ALPHA LITE Co Ltd 2nd Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 Email Tel Fax Web hello alpha lite net 82 2 6317 0464 82 2 2039 0464 www alpha lite net ...

Reviews: