ALPHA 1000

Technical Specifications

LED Chip Type

550W 6 Color + 2 White LED engine

Estimated LED Lifetime (hours) 

50,000

White Light (K) 

2,000~35,000 (VCT/FCT)

Full Color Light 

Full RGB + Amber + Lime + Cyan + Warm White + Cool White 

(7Color Gamut with Hue and Saturation Control)

Color Rendition (%) 

CRI 95~99.5 / TLCI 95~99.5

Dimming (%) 

0~100 (16-bit)

Lens Diameter (mm/inch) 

170 / 6.7

Beam Angle ( °)

15~55

Signal Control 

5-Pin DMX In and Out

Individual Control 

Smart Touch LCD Controller

Supported Protocol 

DMX512 / RDM

(Optional) Supported Protocol 

DMX512 Wireless / RDM Wireless

Remote Device Management 

Supported

Channel Function 

Dimming / CCT / Tint / RGBALC / Cross Fader / Color Macro / Strobe

Power Input Voltage 

AC 100-240V / 50~60Hz

Power Consumption (W) 

240

Ambient Temperature 
Operation ( °C) 

-20~45

Spigot Mounting (mm) 

16 / 28

Tilt Angle ( °)  

+ / - 90

Body Dimensions 
(mm/inch) (WHD)

282 x 337 x 401 / 11.1 x 13.3 x 15.8

Full Dimensions with Manual 
Yoke (mm/inch) (WHD)

366 x 507 x 401 / 14.4 x 20 x 15.8

Body Weight (kg/lbs) 

7.6 / 16.8

Full Weight with Manual Yoke 
(kg/lbs)

8.8 / 19.4

Protection Class 

IP20

* This specification data is based on the aging state of the equipment, 

and the brightness and color temperature before and after aging may be different.

Summary of Contents for a7c Series

Page 1: ...A L P H A 1 0 0 0 A L P H A 1 0 0 0 A L P H A S E V E N C O L O R ALPHA LITE ALPHA LITE USER MANUAL USER MANUAL BOOK BOOK ...

Page 2: ...work Be sure to fix the safety chain on the product when installing and moving Please install the signs below for people to bypass when install the product on high truss The work should be done under the direction of approved specialist who is trained in safety and mechanical installations The brightness and color temperature before and after aging may be different 2 3 4 5 6 1 Precautions ...

Page 3: ...ite Adjust 11 12 13 14 15 16 17 LCD Screen Instruction Safety Information 1 Sleep Mode Function RDM Function Dimming Speed Setup Master Function Fixture ID Number Setup Device Label Setup 18 19 20 Extra Function Temperature Sensor Network Connection 21 Error Information Cross Fader Color Macro 22 Extra Information DMX Protocols RDM Protocols 23 26 Protocols Fixture Information Fixture Exterior Vie...

Page 4: ...t source optical solution for lighting control and an innovative operation interface It is a package lighting composed of LED spot LED panel with 6 Color 2 White ultra high capacity LED engine and ALPHA LITE s unique α Algorithm Overcome the limits of the color expression gamut and color temperature range that existing White lighting and RGB lighting it became possible to expression for Moonlight ...

Page 5: ...4 ALPHA LITE USER MANUAL BOOK Yoke Handle Fixed Knob Fixture Exterior View Smart Touch LCD Screen Connector Panel ...

Page 6: ...5 Product name ALPHA 1000 Dimensions ...

Page 7: ...6 ALPHA LITE USER MANUAL BOOK Pole operation yoke Pan Tilt Soft box Detachable Gemball Detachable Accessory Options ...

Page 8: ... RDM Optional Supported Protocol DMX512 Wireless RDM Wireless Remote Device Management Supported Channel Function Dimming CCT Tint RGBALC Cross Fader Color Macro Strobe Power Input Voltage AC 100 240V 50 60Hz Power Consumption W 240 Ambient Temperature Operation C 20 45 Spigot Mounting mm 16 28 Tilt Angle 90 Body Dimensions mm inch WHD 282 x 337 x 401 11 1 x 13 3 x 15 8 Full Dimensions with Manual...

Page 9: ...8 ALPHA LITE USER MANUAL BOOK 0m 1m 3m 5m 7m 9m 50 863 350 197 127 5600K 5600K Photometry Data Distance m Illuminance lux ...

Page 10: ...ITCH USB PORT for ADMINISTRATOR ONLY Do not connect USB without administrator s permission 1 Observe the proper voltage rang 2 If power is supplied outside the range noise may be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged WARNING 2 3 4 5 1 ...

Page 11: ...X chain User must use an adapter cable for connect the DMX controller to other XLR output Shield Signal Signal Not Connected Not Connected Shield Signal Signal Not Connected Not Connected DMX INPUT XLR Mounting plugs DMX OUTPUT XLR Mounting sockets 1 Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture 2 Connect one output to the input of the next ...

Page 12: ...n the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset Main Screen Locked Fixture ID Screen Locked A A A x 3 x 3 ...

Page 13: ...Adjust the selected function among Intensity Color Temperature and Tint In DMX MODE Current channel mode Display current channel mode Only display on DMX MODE 08 Home Return to the main screen 09 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting ...

Page 14: ...information DMX address input Color temperature setup Saturation setup Master function setup Information Tint setup White setup RDM mode setup DMX channel value Description of each function Individual RGB setup and Preset RGBW value Description of each function Description of fixture ID Information Full screen Dimming speed setup Information Information Fixture ID number input Information Home Mai...

Page 15: ... bottom the current lighting value and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value DMX MODE USER MODE COLOR MODE HOME DMX MODE USER MODE COLOR MODE INFO Product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual download link etc by clicking the INFO but...

Page 16: ...ch channel information and value 1 1 Ch Mode Dimming 3 3 Ch Mode Dimming CCT 5 5 Ch Mode Dimming CCT Tint Cross Fader Color Macro 12 12 Ch Mode Dimming CCT Tint Cross Fader Red Green Blue Amber Lime Cyan Color Macro Strobe Support channels and features vary by product information DMX Mode Channel Change Address Setup In DMX512 MODE screen user can select DMX channel mode on top tap Input DMX512 ad...

Page 17: ...nt OR In DMX mode even if you press the current value on the main screen the bottom bar is not active Activate control bar and adjust value directly according to selected function To return to the previous screen press the INFO button again Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperatur...

Page 18: ...and is displayed from 0 to 100 White The number indicates the current White LED brightness value of the fixture and is displayed from 0 to 100 information COLOR MODE COLOR MODE It is used when the user directly manipulates the equipment COLOR MODE screen Touch the function you want to change Active in Orange Adjust the value with touch or drag Individual RGB value adjustment and saving preset 1 9 ...

Page 19: ...Sleep mode setup Default Off The function to automatically turn off the screen when there is no operation for 30 seconds If OFF it is always on the screen while power is on Master setup Default Off The function to synchronize and user control all connected fixtures without a console connection If OFF the DMX signal will follow RDM setup Default On The function to enable two way wireless communicat...

Page 20: ...r Setup The master slave function allows to synchronize and control all connected lighting fixtures through the DMX signal without a console connection If a problem occurs in the console or communication line it is possible to control the brightness and CCT and color with only the lighting fixture Main screen Setting Touch MASTER SETUP the function turns on 2 Touch Functions available with one set...

Page 21: ... press Enter Move to the FIXTURE ID screen that displays the large size entered value Touch HOME icon to go back to the main screen The fixture ID is displayed in 3 or 4 digits from automatically recognized 4 digits in contents If user do not enter any number the fixture ID is displayed as 001 Main Screen Fixture ID Screen Fixture ID Input Screen It is the number value 001 to 9999 for the manageme...

Page 22: ...sor Network Connection 45 C or less is cyan 46 69 C is yellow 70 C or more is red If the temperature exceeds 75 C the actual LED output will decrease If it exceeds 85 C the actual LED output will be 0 If it exceeds 85 C the actual LED output will be 0 and Temperature Error Please Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even ...

Page 23: ...e the last set color among Ch 5 10 Individual color settings and Ch 11 Color Macro is applied and distributed As the DMX value of Ch 4 increase the brightness of Ch 2 decrease and the brightness of the color set by Ch 5 or Ch 5 11 increase at the same time The DMX value of Ch 4 adjusts the CCT and color brightness and density ratio relative to each other Cross Fader Color Macro 100 0 0 255 Cross F...

Page 24: ...100 Cyan 11 0 255 See DMX Protocols 4 Color Macro 12 0 255 Strobe Mode Channel DMX Value Function 5 1 0 255 0 100 Dimmer 2 0 255 See DMX Protocols 2 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 See DMX Protocols 4 Color Macro Mode Channel DMX Value Function 3 1 0 255 0 100 Dimmer 2 0 255 See DMX Protocols 2 Color Temperature CCT 3 0 119 120 255 S...

Page 25: ...24 125 6150 126 6200 127 128 6250 129 130 6300 131 132 6350 133 6400 134 135 6450 136 137 6500 138 6600 139 140 6700 141 142 6800 143 6900 144 145 7000 146 147 7100 148 7200 149 150 7300 DMX Value Function 151 152 7400 153 7500 154 155 7600 156 157 7700 158 7800 159 160 7900 161 162 8000 163 164 8100 165 8200 166 167 8300 168 169 8400 170 8500 171 172 8600 173 174 8700 175 8800 176 177 8900 178 17...

Page 26: ...9 102 103 106 107 110 111 114 115 118 119 122 123 126 127 130 DMX Value Color Value Color Macro 131 134 135 138 139 142 143 146 147 150 151 154 155 158 159 162 163 166 167 170 171 174 175 178 179 182 183 186 187 190 191 194 195 198 199 202 203 206 207 210 211 214 215 218 219 222 223 226 227 230 231 234 235 238 239 242 243 246 247 250 251 255 DMX Protocols 3 4 3 5 12 Channel Mode Color Macro ...

Page 27: ...lue Channel 0 Neutral No effect 1 255 1 Slow 255 Fast Strobe RDM Protocols 1 3 Parameter ID Discovery command SET command GET command DISC_UNIQUE_BRANCH YES DISC_MUTE YES DISC_UN_MUTE YES DEVICE_INFO YES SUPPORTED_PARAMETERS YES SOFTWARE_VERSION_LABEL YES DMX_START_ADDRESS YES YES IDENTIFY_DEVICE YES YES DEVICE_MODEL_DESCRIPTION YES MANUFACTURER_LABEL YES DEVICE_LABEL YES YES SENSOR_DEFINITION YES...

Page 28: ...f there is no number the default is 001 4 Software Version Label M0E v1 10 v5 27 180928 Software version Disable 5 DMX Personality 1 Ch Mode DMX channel mode and color temperature setting Enable See Table 1 6 DMX Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display onl...

Page 29: ...1 Ch 5000K 1 Ch Mode 5000K Color Temperature 1 Ch 5600K 1 Ch Mode 5600K Color Temperature 1 Ch 6000K 1 Ch Mode 6000K Color Temperature 1 Ch 10000K 1 Ch Mode 10000K Color Temperature 1 Ch 30000K 1 Ch Mode 30000K Color Temperature 1 Ch 35000K 1 Ch Mode 35000K Color Temperature Table 1 RDM Protocols 3 3 Error Message No Condition Level Description Display 1 Sensor Over Temp Warning Fixture temperatur...

Page 30: ... Tel 82 2 6317 0464 Fax 82 2 2039 0464 E mail hello alpha lite net Web www alpha lite net 2 4 Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 ALPHA LITE USER MANUAL BOOK ...

Reviews: