Operation
34
900-0117-01-00 Rev A
The <
Datalog>
soft key shows amp-hour, watt-hour, and SOC statistics. These maintain a continuous
daily log, up to 128 days, which can be recalled. One day can be displayed at a time.
Figure 18
DataLog Soft Key Screen (with FLEXnet DC)
Soft Keys:
<
+Day>
advances the display forward by a single day. If
the display reads “Today”, it does nothing.
<
–Day>
advances the display backward by a single day
and will display the selected date.
<
Back
> returns to the previous screen.
Screen Items:
Today
The item in the upper left corner
shows the date of the selected Datalog
screen. The current Datalog screen reads
"Today."
Minimum SOC
shows the lowest battery
state of charge (SOC) for that day.
Input
shows the number of amp-hours and
kilowatt-hours brought into the batteries
that day.
Output
shows the number of amp-hours
and kilowatt-hours removed from the
batteries that day.
Net
shows the net gain or loss in
amp-hours or kilowatt-hours that day. This
is the difference between the Input and
Output fields.