Operation
900-0117-01-00 Rev A
33
The <
Shunts>
soft key shows the operation of up to three shunts on the battery monitor. If a shunt has
not been enabled (see page 108), it will read 0.
Figure 17
Shunts Soft Key and Shunt Data (with FLEXnet DC)
Screen Items:
A:
,
B:
, and
C:
These lines display individual readings
from the A, B, and C shunts. Each line shows the
current and kilowatts measured on the shunt at that
time, and the amp-hours and kilowatt-hours
accumulated that day.
Screen Items:
Returned to Battery
and
Removed from
Battery
show the total accumulated amp-hours
that have been delivered to the battery bank (as
charging) or removed from the battery bank (as
loads).
Max Charge Rate
and
Max Discharge Rate
show the highest level of current that was
registered either entering (charging) or leaving
(discharging) the batteries. The
Reset Max
soft
key can reset both numbers at once.
Soft Keys:
The <
Next>
soft key presents the next shunt in
alphabetical order.
<
Back
> returns to the previous screen.
Soft Keys:
<
Shunt A>, <Shunt B>,
and
<Shunt C>
shows long-term
statistics for each shunt. If a shunt has not been enabled
(see page 107), its statistics will read 0.
<
Back
> returns to the previous screen.
Summary of Contents for OutBack Power MATE3
Page 1: ...MATE3 System Display and Controller Owner s Manual ...
Page 22: ...Installation 20 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 142: ...Troubleshooting 140 900 0117 01 00 Rev A THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 144: ...Specifications 142 900 0117 01 00 Rev A NOTES ...
Page 159: ......