Operation
19
(06/2016)
Table 7, Light On/Off
Table 8, Light On+ Timer
Figure 14, Light On/Off Working Time
Light On/Off
Mode
Function
Light On Voltage
(Night Threshold)
When the input voltage of the solar module is lower than the Light On voltage, the load output is turned
on automatically, given that the battery capacity is sufficient and there are no abnormal conditions.
Light Off Voltage
(Day Threshold)
When the input voltage of the solar module is higher than the Light Off voltage, the load ouput is
automatically turned off.
Delay Time
During this period, if the light signal voltage continues to match the Light On/Off voltage, it will carry out
any corresponding actions (Adjustment Range: 0~99min).
Light On+ Timer
Mode
Function
Whenever the working time
is set to 0, there will not be
a working period. The real
working time of T2 depends
upon the Night Time and the
length of T1 and T2.
Working Time 1(T1) The working period of the load after the light control turns on the load.
Working Time 2 (T2) The working period of the load before the light controls turns off the load.
Night Time
Total calculated night time of the controller.
Light Off
Dusk
Night Time
Dawn
Light Off
Light On
Light On
Working Time 1
Working Time 2