User Manual
HRU-SlimAIR
3. Mobile application – to use mobile application you need to have HRQ-GATE bridge paired with the unit
and properly configured Internet access. With PremAir application you can: change fans speed, check HRU
status (normal mode, frost protection mode on, etc.) check faults, check temperatures and many more. To
check all options of application download it for free from Google Play or App Store by typing in „PremAir”.
Default settings for SlimAIR-250:
Tag
Speed
Air flow
efficiency
[%]
Air flow
efficiency
[m
3
/h]
Setting
SlimAIR-250-H
SlimAIR-250E-H
SlimAIR-250-H-CF SlimAIR-250E-H-CF
#63
Low Supply
15
37.5
24
22
15
15
#64
Low Exhaust
23
20
15
15
#65
Med. Supply
50
125
45
45
50
50
#66
Med. Exhaust
44
44
50
50
#67
High Supply
70
175
57
56
70
70
#68
High Exhaust
54
56
70
70
#149 Boost Supply
100
250
78
77
100
100
#150 Boost Exhaust
75
77
100
100
Default settings for SlimAIR-350:
Tag
Speed
Air flow
efficiency
[%]
Air flow
efficiency
[m
3
/h]
Setting
SlimAIR-350
SlimAIR-350E
SlimAIR-350-CF
SlimAIR-350E-CF
#63
Low Supply
15
52.5
14.5
12.5
15
15
#64
Low Exhaust
15
15
15
15
#65
Med. Supply
50
175
28
25
50
50
#66
Med. Exhaust
31
31
50
50
#67
High Supply
70
245
33
31
70
70
#68
High Exhaust
37.5
41
70
70
#149 Boost Supply
100
350
47
46
100
100
#150 Boost Exhaust
52.5
60
100
100
Default settings for SlimAIR-500:
Tag
Speed
Air flow
efficiency
[%]
Air flow
efficiency
[m
3
/h]
Setting
SlimAIR-500
SlimAIR-500E
SlimAIR-500-CF
SlimAIR-500E-CF
#63
Low Supply
15
75
14.5
14
15
15
#64
Low Exhaust
15
15
15
15
#65
Med. Supply
50
250
33
30.5
50
50
#66
Med. Exhaust
33
35.5
50
50
#67
High Supply
70
350
42.5
40
70
70
#68
High Exhaust
43
48
70
70
#149 Boost Supply
100
500
63
58.5
100
100
#150 Boost Exhaust
62
72.5
100
100