28. HEATER INSTALLATION
Mount the heater as shown in the manufacturer's instructions. The heater should be
mounted on Wall Section E, over the vents and 7” from the floor of the sauna. All the
necessary hardware is supplied with the heater.
Drill a hole below and behind the heater to run the wire and/or conduit according to local
electrical codes. The heater will be hard
-
wired according to the specific wiring require-
ments for your heater.
Do not attempt to wire the heater yourself. Contact a licensed electrician in accordance
with your local electrical codes. Heater brand may vary depending on where the sauna
was purchased. Install sauna stones in accordance with heater manufacturer instructions.
Typical wiring requirements for distances of up to 30 feet from the breaker box are as follows:
4.5kw
-
6.0kw heaters require 10
-
2 w/ground, copper wire only, and 30amp non
-
GFCI breaker.
8.0kw 8
-
2 w/ground, copper wire only, and 40amp non
-
GFCI breaker.