When the procedure is completed, the MIC displays the sequence that
follows:
VALID COEFFICIENTS
REMOVE THE SEAL
PUT BACK THE SEAL
The new coefficient and flow rates values are taken into account.
6.1.2 Gravity mode
This menu is used to do a check of the accuracy of the measuring system.
First, make a gravity discharge (USER mode) to fill a tank prover or through a master
meter.
Enter the reference volume (read on the gauge and corrected), then validate. The
MIC displays the information that follows:
The signed error in percent (%)
The coefficient revised as a function of the error
The average flow.
ENTER STANDARD VALUE
GRAVITY MODE
0100
1
.4
L
ENTER QUANTITY (REF)
-00.33
ERROR (PERCENT)
0.2
CORRECTION
27.3
AVERAGE FLOWRATE
L kg/
m
3
/h
6.2 Menu PRODUCT SETTINGS
PRODUCT SETTINGS
1
FOD+
16
You can configure 16 different products. Default names of the first six products: FOD+, FOD,
GO+, GO, GNR+, GNR.
EM
: For DUAL only. Assign the product to one or both measuring systems (EMA, EMB or
EMA+EMB)
NAME
: Record or enter the name of the product
DENSITY
AT
XX
:
XX
is
the
reference
temperature
set
in
menu
METROLOGICAL>CONFIGURATION>CONVERSION>DENSITY TEMP. (REF)
. Set the density in
Kg/m
3
PRODUCT TYPE
: Select the product quality
UNIT PRICE/DEF
: Enter the numeric value of the default unit price
U.P.
: Select if the price includes taxes or not
PRICE IN
: Select the unit of the price. This menu depends on the currency set in menu
CONFIGURATION>CURRENCY
VAT RATE
: Record the tax rate (in %).
ADDITIVE SETTINGS
–
Access restricted to the Maintenance
: If the DUAL TRONIQUE controls
an additive injection device, you must configure the parameters that follow:
VOLUME/PULSE
: Record the volume of primary product. For example “00200”: the
DUAL TRONIQUE puts a dose of additive every 200 liters of primary product (minimum
value: 10L).
INJECTOR
: The number of injectors is given by the metrological configuration
INSTRUMENTATION>ADDITIVE INJECTOR