SET THE DUAL TRONIQUE: SUPERVISOR MODE
SETTINGS
(1)
TIME ADJUSTMENT
PRODUCT SETTINGS
(1)
CALIBRATION/ GAUGE
PRINTER SETTINGS
(1)
LANGUAGE
CONFIGURATION
(1)
DSPGI
ICOM MENUS
(1)
COMPUTING
The access to the red boxes menus is restricted to the Maintenance with a red key.
(1)
: The sub-menus are different according to the level of access: Level-User, Level-Manager and
Level-Maintenance.
6.1 Menu CALIBRATION/ GAUGE
This menu depends on the number and type of measuring systems installed on the road
tanker. The calibration is the same for all measuring systems.
EMA
LINEARISATION/FLOW
EMB
CALIBRATION/ GAUGE
ENTER STANDARD VALUE
LINEARISATION/FLOW
ENTER STANDARD VALUE
6.1.1 Pumped mode
6.1.1.1 Sub-menu ENTER STANDARD VALUE
This menu allows you to check the accuracy of the measuring system by calculating
the measuring device error, the new corrected coefficient and the average flow.
If the system manages two measuring systems, choose the relevant one: EMA or
EMB.
First, make a discharge (USER mode) in high or low flow with predetermination of the
volume to fill a tank prover or through a master meter.