Safety instructions for the installation 
 

- ALL95100 is just for network interface cards, hubs, switches and 

other network equipment. 

- Never install the ALL95100 during a electric storm!  

- Only for installation in cool, dry rooms. 

- Power off all devices which should be prevented before 

installation. 

- ALL95100 must be connected to ground. 

- To prevent electrical shock while installing the ground wire to the 

electrical power outlet ground, disconnect electricity to the outlet. 

From the electrical panel, switch off the appropriate circuit breaker 

or remove the fuse. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ALL95100

Page 1: ...ALL95100 Gigabit CAT 6 Surge Arrester For 10 100 1000Mbit Ethernet PoE Quick Installation Guide ...

Page 2: ...5100 during a electric storm Only for installation in cool dry rooms Power off all devices which should be prevented before installation ALL95100 must be connected to ground To prevent electrical shock while installing the ground wire to the electrical power outlet ground disconnect electricity to the outlet From the electrical panel switch off the appropriate circuit breaker or remove the fuse ...

Page 3: ...d 2 Disconnect the network cable from the device which should be prevented 3 Connect this network cable with one port of the ALL95100 4 Connect one end of another network cable with the second port of the ALL95100 5 Connect the other end of this network cable to the device which should be prevented 6 Connect the yellow green ground wire with an external grounding conductor ALL95100 Grounding condu...

Page 4: ...Clamping 15V 5ns 30Apk Pair wire to wire Diff Capacity 4 0pF PoE able IEEE802 3af at LTPoE up to 90W Operating Temperature 15 C to 65 C ESD IEC 61000 4 2 class 4 10kV CD Relative Humidity 95 non condensing Lines Protected Pins 1 8 on 8 pinned modular jack Standard Compliance IEEE 802 3 CAT 5 6 Please note We recommend that the protective conductor should be installed by a qualified electrician ...

Page 5: ...above directive is indicated by the CE sign on the device The Allnet ALL95100 conforms to the Council Directives of 2004 108 EC This equipment meets the following conformance standards IEC61000 4 6 2009 IEC61000 4 8 2010 IEC61000 4 11 2004 IEC60950 1 2006 A11 2009 A1 2010 This equipment is intended to be operated in all countries This declaration is made by ALLNET Computersysteme GmbH Maistraße 2 ...

Reviews: