16
4
19
5
20
10
7
8
9
11
8. Setting the welding parameters
A.
Press the
locking clamping lever (10)
and swing the
clamping lever (7)
up until the lock engages. Use your
other hand to accomplish this by holding the automatic welder firmly by the
handle
(11)
. Unlock the
welding
force safety bolt (9)
by pulling and rotating 90°. Set the
clamping arm (4)
to the maximum opening using the
welding force adjustment ring (8)
.
B.
While unclamped, detach the
lower contacting system locking screw (20)
. Screw the
lower contacting
system setting screw (19)
a sufficient distance away from the
welding wedge (5)
using a 4 mm socket
wrench.
CAUTION!
The welding wedge is set to 2 mm membranes in the factory settings.
The welding wedge (5) must be cooled down for adjustment purposes.
Danger of crushing when closing the clamping arm (4).
Welding force and contacting system
Switch off GEOSTAR with the
main switch (2)
and disconnect from the mains.