507582-04
Page 41 of 54
Issue 2220
Flame Sense
Humidifier
ECM DRIVE - 24VAC
Accessories
Line Voltage
Line Voltage
Ignitor and Combustion
Air Inducer
Neutrals
On Board Links
Thermostat Connections
3/16” QUICK CONNECT TERMINALS
HI COOL (24VAC)
LO COOL (24VAC)
HI HEAT (24VAC)
LO HEAT (24VAC)
PARK (two un-powered terminals for unused motor
speed taps)
FLAME SENSE
¼” QUICK CONNECT TERMINALS
HUM (two un-powered, normally open/dry contacts)
ACC (one 120VAC output terminal for optional accessory)
L1 (three 120VAC line terminals)
Neutrals (five 120VAC neutral terminals)
THERMOSTAT CONNECTIONS
DS= Dehumidification signal
W2= Heat demand from 2nd stage Tstat
W1= Heat demand from 1st stage Tstat (white)
R= Class 2 voltage to thermostat
G= Manual fan from Tstat (green)
C= Tstat signal ground connected to transformer
Ground (TR) & Chassis ground (GRD)
Y1= Tstat 1 st stage cool signal
Y2= Tstat 2 nd stage cool signal
DH= NOT USED
H= NOT USED
L= NOT USED
UTEC TWO-STAGE CONSTANT TORQUE INTEGRATED FURNACE CONTROL
Figure 59.
UTEC Integrated Furnace Control 107047-xx