Pike Technical Manual
V5.2.0
353
Configuration of the camera
Advanced register: frame counter
The
frame counter
feature is controlled by the following advanced feature reg-
ister:
Having this feature enabled, the current
frame counter
value (images read out
of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit integer
value into any captured image.
Setting the
Reset
flag to 1 resets the frame counter to 0: the
Reset
flag is self-
cleared.
Additionally there is a register for direct read out of the frame counter value.
Note
Different to Marlin SIS:
Register 610 is only to be used to reset the frame counter.
Register
Name
Field
Bit
Description
0xF1000610 FRMCNT_STAMP
Presence_Inq
[0]
Indicates presence of this feature
(read only)
Reset
[1]
Reset frame counter
---
[2..31]
Reserved
0xF1000614 FRMCNT
[0..31]
Frame counter
Table 189: Advanced register:
Frame counter
Note
The 4 bytes of the
frame counter
value will be inserted as the
5th to 8th byte of a line
.