Camera Link registers
106
Goldeye Camera Link Register Controls Reference V1.0.0
RegFloatRegNUCDatasetTemperature
Sensor temperature, at acquisition of the data set indexed by
Reg
NUCDatasetSelector
. The data set should be selected so that the actual
sensor temperature is close to the reference temperature.
RegNUCMode
Controls the operating mode of the non-uniformity correction. Depending on the
factory-provided correction data, different modes may be available.
The number of distinct reference values is limited by available correction data,
depending on the camera model.
Register name
RegFloatRegNUCDatasetTemperature
Register type
FloatReg
Access mode
R
Unit
Degree Celsius (°C)
Address
0x00090048
Length (Bytes)
4
Bits used
31..0
Register name
RegNUCMode
Register type
MaskedIntReg
Access mode
R/W
Address
0x00090000
Length (Bytes)
4
Bits used
31..28
Enumeration values:
Value
Name and description
0
Off
Image data is passed through unchanged.
1
TwoPoint
Uses a dark reference image and a bright reference image to calculate
offset and gain for each pixel and correct the non-uniformity
accordingly.