Temperature control
232
Goldeye G/CL Technical Manual V4.2.0
Neutralization of the temperature influence
To control the temperature influence on the non-uniformity, the TEC element
keeps the sensor temperature at predefined setpoints, preferably the default
setpoint.
Temperature setpoints
A set of correction data is applied to the output signal. This correction data set is
predetermined for each camera individually and is optimized for the default
temperature setpoint. The correction data set is uploaded into the camera during
manufacturing.
Model
Setpoint 1
Setpoint 2 Setpoint 3 Setpoint 4
Goldeye CL models
CL-008 TEC1
+20 °C
1
(Default) +25 °C
+35 °C
+50 °C
CL-008 Cool TEC1
-5 °C (Default) +5 °C
+10 °C
+20 °C
CL-032 TEC1
+5 °C (Default) +20 °C
+35 °C
+50 °C
CL-032 Cool TEC2
(Default) -20 °C
-5 °C
+10 °C
(N/A)
CL-033 TEC1
+5 °C (Default) +20 °C
+35 °C
+50 °C
CL-033 TECless
(Not applicable to TECless models.)
CL-034 TEC1
+5 °C (Default) +20 °C
+35 °C
+50 °C
Goldeye G models
G-008 TEC1
+20 °C
1
(Default) +25 °C
+35 °C
+50 °C
G-008 Cool TEC1
-5 °C (Default) +5 °C
+10 °C
+20 °C
G-032 TEC1
+5 °C (Default) +20 °C
+35 °C
+50 °C
G-032 Cool TEC2
(Default) -20 °C
-5 °C
+10 °C
(N/A)
G-033 TEC1
+5 °C (Default) +20 °C
+35 °C
+50 °C
G-033 TECless
(Not applicable to TECless models.)
G-034 TEC1
+5 °C (Default) +20 °C
+35 °C
+50 °C
1
The first temperature setpoint may be set lower than +20 °C. However, if the sensor
temperature is lower than the ambient temperature, especially in humid environments,
condensation may occur.
Table 142: Defined temperature setpoints for Goldeye cameras