Specifications
52
Goldeye G/CL Technical Manual V4.1.1
Operating conditions
Mass, with C-Mount adapter
320 g
Mass, with F-Mount adapter
370 g
Mass, with M42-Mount adapter 340 g
Parameter
Values
Operating temperature
-20 °C to +55 °C (case)
Storage temperature
-30 °C to +70 °C (ambient)
Temperature setpoints
+25 °C (default and calibrated)
+20 °C, +35 °C, +50 °C (other setpoints)
or user-confugurable
Relative humidity
10 % to 95 %, non-condensing
Power requirements (DC)
10.8 V to 30.0 V
Max. power consumption
10 W (@ 12 VDC)
Typical power consumption
without cooling
4.5 W (@ 12 VDC)
2
Even though the first temperature setpoint is pre-configured to +20 °C, it is
possible to set it to a lower temperature. However, if the sensor temperature is
lower than the ambient temperature, especially in humid environments,
condensation may occur.
Table 12: CL‐008 SWIR TEC1 ‐ Operating conditions
Parameter
Values
Table 11: CL‐008 SWIR TEC1 ‐ Mechanics specifications(sheet 2 of 2)