Triggering
163
Goldeye G/CL Technical Manual V4.1.1
Test conditions
•
External 2.4 kOhm resistor to GND
•
Power input for output ports set to 12 V
Control signals
It is possible to configure the inputs and outputs of the camera, using software.
The different modes are described on the following pages.
For a general description of the outputs and warnings see chapter
Figure 51: Goldeye G/CL output switching times
Cycle delay:
The cycle delay for the Goldeye is as follows:
t
pdLH
< 3.5 µs
t
pdHL
< 30 µs
For this reason, we recommend triggering on the rising edge. This ensures the
fastest possible reaction time.
I
F
0
I
C
100%
90%
10%
t
t
0
delay time
rise time
turn-on time
storage time
fall time
turn-off time
Optocoupler input
(internal)
Optocoupler output
(external)
t
off
(= t
s
+ t
f
)
t
d
t
r
t
on
(= t
d
+ t
r
)
t
s
t
f
t
d
t
on
t
r
t
s
t
f
t
off