GenICam for CSI-2 Access - Camera operation
Need to restart the embedded board
Whenever you
change between different access modes
:
• You must restart the embedded board.
• Closing the application while the camera is streaming is not sufficient.
Device reset
The
DeviceReset
command does not work.
User sets
Settings, including user sets are not transferred between the access modes.
Before you switch from
GenICam for CSI-2 Access
to another access mode, disable
individual user sets. Set
UserSetDefault
and
UserSetSeletor
to
Default
to
enable factory settings.
Camera ramp up
Frame rates and CPU load
When you start streaming Alvium CSI-2 cameras with a GenICam compliant viewer,
the maximum frame rate may not be achieved for maximum resolution at first. In
addition, the CPU load may increase significantly. After a few minutes, the stream
has stabilized, the maximum frame rate is achieved, and the CPU load decreases by
20%.
Lost frames with Python API
If the camera is operated at high frame rates and low exposure times, initial frames