Pike
Technical
Manual
V5.2.3
317
Configuration of the camera
Configuration
of
the
camera
Standard Parameter Update Timing
The
camera
behaves
like
older
firmware
versions
without
this
feature.
The
UpdActive
flag
has
no
meaning.
Quick Format Change Mode
This
mode
behaves
like
Standard Parameter Update Timing
mode
with
the
following
exception:
An
already
started
image
transport
to
the
host
will
not
be
interrupted,
but
an
already
started
integration
will
be
interrupted.
To
switch
on
Quick Format Change Mode
do
the
following:
1.
Set
UpdTiming
to
2.
2.
Set
UpdActive
to
1.
3.
Be
aware
that
all
parameter
values
have
to
be
set
within
10
seconds.
Note
For
a
detailed
description
see
Register
Name
Field
Bit
Description
0xF1000570
PARAMUPD_TIMING Presence_Inq
[0]
Indicates
presence
of
this
feature
(read
only)
---
[1
to
5]
Reserved
UpdActive
[6]
Update
active
See
0:
(default);
reset
to
0
means
Encapsulated Update end
1:
set
to
1
means
Encapsulated Update begin
---
[7
to
23] Reserved
UpdTiming
[24
to
31] Update
timing
mode
If
set
to
O:
Standard Parameter Update Timing
is
active
If
set
to
2:
Quick Format Change Mode
is
active
Table 181: Advanced register: Update timing modes