TROUBLESHOOTING/ERROR CODES 

 

Error 
Code 

Error  

Description 

Resolution 

0072  Duplicate Punch 

This time card was already punched IN or OUT less than a minute ago. 
Please allow a few extra minutes prior to punching again. 

0021  Low Power 

Insufficient Power Voltage. Please connect the time clock to the 
proper Power Outlet. 

0091  Motor Error 

Check Motor Cable: call customer support at 888-860-2535 

0092  Card Motor Error   Unable to load Time Cards: call customer support at 888-860-2535 

0093  Internal Error 

Memory IC issue: call customer support at 888-860-2535 

0094  Sensor Issue 

Card Number not supported or Sensor not responding: call customer 
support at 888-860-2535 

0071 

Wrong Side  of 
Time Card 

Insert the time card to correct side. 

 

 

Summary of Contents for AT-2700

Page 1: ...Page 1 Allied Time USA Model AT 2700 Time Recorder User Manual Version 0 2...

Page 2: ...the back side of the card You can record up to 90 total punch times using a single time card during any given pay cycle Always start with a new time card at the beginning of each pay cycle and rememb...

Page 3: ...play Hour Format 4 1 7 Printed Hour Format 4 1 8 Printed Minutes Format 4 1 9 Day Change Time 5 1 10 Daylight Savings Time 5 1 11 Setup Pay Cycle 5 PAY WEEKLY 5 PAY BI WEEKLY 5 PAY SEMI MONTHLY 5 PAY...

Page 4: ...nter again to confirm 1 4 Setup Time Hour SET HOUR 08AM use to enter adjust hour To make changes press Enter select desired hour using then press Enter again to confirm 1 5 Setup Time Minutes SET MINU...

Page 5: ...ter and use buttons to enter Day of the week Date and Month of current month for your Bi Weekly Pay Cycle beginning date For example your pay cycle started on Monday January 6th and will continue for...

Page 6: ...ed Time at 888 860 2535 for special reset instructions 3 Clear Data CLEAR DATA NO This function will allow you to clear out the clocking in sequence stored in the machine Press Enter use keys to selec...

Page 7: ...w a few extra minutes prior to punching again 0021 Low Power Insufficient Power Voltage Please connect the time clock to the proper Power Outlet 0091 Motor Error Check Motor Cable call customer suppor...

Page 8: ...re on ribbon holders grab ribbon handle with the other hand as shown in figure below and gently lift up the ribbon to remove from the holder Insert New Replacement ribbon by snapping it on the cartrid...

Reviews: