C613-50170-01 Rev B
Command Reference for x510 Series
2625
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
LLDP C
OMMANDS
LLDP
REINIT
lldp reinit
Overview
This command sets the value of the reinitialization delay. This is the minimum time
after disabling LLDP on a port before it can reinitialize.
The
no
variant of this command sets the reinitialization delay back to its default
setting.
Syntax
lldp reinit <
1-10
>
no lldp reinit
Default
The default reinitialization delay is 2 seconds.
Mode
Global Configuration
Examples
To set the reinitialization delay to 3 seconds, use the commands:
awplus#
configure terminal
awplus(config)#
lldp reinit 3
To set the reinitialization delay back to its default, use the commands:
awplus#
configure terminal
awplus(config)#
no lldp reinit
Related
Commands
Parameter
Description
<
1-10
>
The delay in seconds.