C613-50170-01 Rev B
Command Reference for x510 Series
2195
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
G.8032 E
THERNET
R
ING
P
ROTECTION
S
WITCHING
C
OMMANDS
PROFILE
NAME
profile name
Overview
Use this command to associate a G.8032 profile instance with this G.8032 Ethernet
Ring Protection (ERP) instance.
Syntax
profile name <
erp-profile-name
>
Default
If this command is not used, a profile with the name “default-profile” will be used
for this G.8032 ERP instance.
Mode
G8032 Configure Switch Mode
Usage
A G.8032 ERP instance uses a profile which contains timer configurations and
configurations for revertive modes of operation. This configuration can be
accepted regardless of the ERP instance being disabled or enabled. Any
parameters from a changed profile will take effect the next time the G.8032 state
machine uses the parameters in the updated profile.
Example
To associate a G.8032 profile named “prof_1” with a G.8032 ERP instance named
“blue”, use the following commands:
awplus(config)#
g8032 erp-instance blue
awplus(g8032-config-switch)#
profile name prof_1
Related
Commands
Command
changes
Version 5.4.7-0.1: command added
Parameter
Description
<erp-profile-name>
The name of the G.8032 profile