Environmental Specifications
Warning
You must use a UL Listed 3X or 4X enclosure when installing the
device in an outdoor environment.
Table 16. Operating Temperature Ratings
Model Name
Operating Temperature Ranges
1
Rating
Enclosure Type
Sealed
Enclosure:
0 lfm
Ventilated
Airflow:
240 lfm
Cooling Fan
Airflow:
2150 lfm
IE340-12GP
-40°C to 75°C
(-40° F to 167° F)
-40°C to 65°C
(-40° F to 149° F)
-40°C to 70°C
(-40°F to 158°F)
-40°C to 75°C
(-40°F to 167°F)
IE340-12GT
-40°C to 75°C
(-40°F to 167°F)
IE340-20GP
-40°C to 65°C
(-40° F to 149° F)
-40°C to 70°C
(-40°F to 158°F)
-40°C to 75°C
(-40°F to 167°F)
IE340L-18GP
-40°C to 65°C
(-40° F to 149° F)
-40°C to 55°C
(-40°F to 131°F)
-40°C to 65°C
(-40°F to 149°F)
1. These values are for vertical mounting orientation. For horizontal mounting orientation, reduce the
maximum values by 5
°
C.
Table 17. Environmental Specifications
Storage Temperature
-40° C to 85° C (-40° F to 185° F)
Operating Humidity
5% to 95% noncondensing
Storage Humidity
5% to 95% noncondensing
Maximum Operating Altitude
3,000 m (9,843 ft)
Table 18. Ingress Protection
IE340 Switch
IP30
Summary of Contents for IE340 Series
Page 10: ...IE340 Series Installation Guide 10...
Page 14: ...Tables 14...
Page 18: ...IE340 Series Installation Guide 18...
Page 52: ...IE340 Series Installation Guide 52...
Page 62: ...IE340 Series Installation Guide 62 Figure 13 Space Issue Between SFP Module and Copper Port...
Page 68: ...IE340 Series Installation Guide 68...
Page 86: ...IE340 Series Installation Guide 86...
Page 94: ...IE340 Series Installation Guide 94...