SwitchBlade x8106 Chassis Switch and AT-SBx81CFC400 Card Installation Guide
187
Monitoring the Initialization Process
The line and controller cards perform an initialization process when you
power or reset the chassis. The initialization process takes approximately
two minutes to complete. The line cards do not begin to forward traffic from
their ports until the process is finished.
The process has two phases. In the first phase, which takes approximately
one minute, the controller card loads and initializes its AlliedWare Plus
Operating System and, if there are two controller cards in the chassis, sets
its active or standby state. In the second phase, the Ethernet line cards
receive their management software from the active controller card,
initialize the software, and configure their parameter settings according to
the configurations provided by the active controller card. This phase also
takes one minute, after which, the line cards begin to forward traffic.
You may monitor the initialization process by viewing either the LEDs on
the cards or the messages on the Console port, as explained in the
following sections.
Using the LEDs
to Monitor the
Initialization
Process
To monitor the first phase of the initialization process in which the
controller card initializes its AlliedWare Plus Operating System and
establishes its active master or standby master state, examine the CFC
LED in the System Status LEDs on the card. The LED flashes green while
the card initializes its management software. When this phase is finished,
the card changes the LED to solid green if it is the active master or solid
amber if it is the standby master.
To monitor phase 2 in which the line cards initialize and configure their
management software, watch the SBx Linecard Status LEDs. There are
twelve LEDs (numbered 1 to 12), one for each slot. The LED for a slot
flashes green while the corresponding line card initializes its management
software and configures its settings in accordance with the settings from
the active controller card. The LED changes to solid green when the line
card completes the initialization process and begins forwarding traffic.
Using the Console
Port to Monitor
the Initialization
Process
Another way to monitor the initialization process of the chassis is to
connect a terminal or PC with a terminal emulator program to the Console
port on the controller card and watch the status messages. If the chassis
has two controller cards, you should use the Console port on the controller
card in slot 5. (The settings for the terminal or terminal emulator program
are found in “Using Local Management to Verify the Chassis” on
page 194.) Figure 126 on page 188 and Figure 127 on page 189 illustrate
the messages. The controller and line cards are fully initialized and
forwarding network traffic when the Console port displays the “awplus
login” prompt.
Summary of Contents for AT-SBx8
Page 8: ...Contents 8...
Page 12: ...List of Figures 12...
Page 14: ...List of Tables 14...
Page 18: ...Preface 18...
Page 32: ...Chapter 1 Chassis and Power Supplies 32...
Page 118: ...Chapter 6 Installing the Power Supplies 118...
Page 134: ...Chapter 7 Installing the AT SBx81CFC400 Controller and Ethernet Line Cards 134...
Page 152: ...Chapter 8 Installing the Transceivers and Cabling the Ports 152...
Page 190: ...Chapter 9 Powering On the Chassis 190...
Page 212: ...Chapter 11 Troubleshooting 212...