Chapter 7: Configuring the Switch for Stand-alone Operations
80
Determining the Status of the VCStack Feature
After the switch has initialized its management software, examine the
switch ID LED on the front panel and do one of the following:
If the LED is displaying “0,” the VCStack feature is disabled and
the switch is ready for network operations as a stand-alone unit.
Go to Chapter 6, “Installing SFP and SFP+ Transceivers” on page
73, to continue with the installation.
If the LED is displaying a number other than “0,” you need to
disable the VCStack feature to use the switch as a stand-alone
unit.
You can disable the VCStack feature from a local management session of
the switch using the Console port. To start a local management session,
go to “Starting a Local Management Session” on page 81.
Caution
You must reset the switch to disable the VCStack feature. If the
switch is already connected to a live network, some network traffic
may be lost.
Note
The initial management session of the switch must be from the
Console port.