50
60549
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
o. Rear Mounting Brackets:
(1) Remove five screws holding rear mounting
brackets to rear of dryer cabinet. Refer to
Figure 22.
57. TERMINAL BLOCK OR POWER CORD
a. Terminal Block – Electric Models (Refer to
Through Serial No. S6271975XG:
(1) Remove access plate on rear of cabinet.
(2) Remove all wires from terminal block.
NOTE: Refer to appropriate wiring diagram when
rewiring terminal block.
(3) Remove screws holding terminal block to
bracket.
NOTE: Do not let terminal block insulation drop
when removing the block. Insulation must be in
place when reinstalling block.
Starting Serial No. S6271976XG:
(1) Remove two screws from the bottom edge
of the front panel. Refer to Figure 12.
(2) Swing the bottom of the panel away from
the dryer to disengage hold-down clips and
guide lugs from cabinet top. Refer to
Figure 12.
(3) Disconnect wires from door switch. Refer
to Figure 13.
NOTE: Refer to the appropriate wiring diagram
when rewiring the switch.
(4) Remove two cabinet hold-down screws.
Refer to Figure 30.
(5) Lift cabinet top to a vertical position by
hinging it on the rear hold-down brackets.
Refer to Figure 36.
NOTE: When servicing, cabinet top may be raised
and hinged on the rear hold-down brackets, or
supported against wall behind the dryer.
(6) Remove all wires from terminal block.
NOTE: Refer to appropriate wiring diagram when
rewiring terminal block.
(7) Remove screw holding terminal block to
bracket. Refer to Figure 36.
Figure 35
DRY866S
REAR
BULKHEAD
HEATER
BOX
ATTACHING
SCREWS
HEATER
BOX