14. TIMER/ELECTRONIC CONTROL DOES NOT ADVANCE IN AUTOMATIC CYCLE
DRY1879S
Electronic control models:
Control does not advance in
automatic cycle.
Is exhaust
system
improper or
inadequate?
Refer to
Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Is cycling
thermostat
inoperative?
Test thermostat
and replace if
inoperative.
Yes
Are seals
inoperative
(air leaks)?
Check and replace any
inoperative seals in the
following areas:
1. Seal between loading
door and front panel.
2. Seal between front panel
and front bulkhead.
3. Seal between blower
cover and air duct.
4. Seal between cylinder
and front or rear bulkhead.
5. Gap between air duct and
filter mounting.
Yes
Timer
models: Is
resistor
inoperative?
Test resistor
and replace if
inoperative.
Heater
assembly
does not heat
or burner does
not ignite?
Refer to
Dryer
Heating
Assembly Does
Not Heat or
Burner Does
Not Ignite
paragraph.
Heater assembly
or burner cycles
off prematurely?
Refer to
Dryer
Heater
Assembly or
Burner Shuts
Off Prematurely
paragraph.
Is large
load
drying?
Timer or electronic
control will not
advance until the
load is almost dry.
Is wiring
broken,
loose or
incorrect?
Refer to wiring
diagram.
Electronic
control:
Is control
inoperative?
Select a moisture
dry setting to see if
machine stops after
approximately
six minutes.
If not, inspect bar
sensor/wiring.
Timer models: Timer does not
advance in automatic cycle.
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Yes
No
Timer
models:
Is timer motor
inoperative?
Select a drying
cycle and activate
start switch. Rotate
timer knob until
signal sounds.
Release timer
knob. Signal should
stop within ten
minutes. If not,
replace timer.
No
Yes