background image

www.alliancelaundry.com

Installation

Washer-Extractors

Cabinet Freestanding

Refer to for Page 5 Model Identification

Part No. D1343ENR3

November 2012

Original Instructions
Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

CFD

CFD644N

Summary of Contents for UX18

Page 1: ...actors Cabinet Freestanding Refer to for Page 5 Model Identification Part No D1343ENR3 November 2012 Original Instructions Keep These Instructions for Future Reference If this machine changes ownershi...

Page 2: ......

Page 3: ...tallation 17 Frame Dimensions and Mounting Bolt Location For 12 lb 60 l 14 lb 65 l 18 lb 75 l and 25 lb 100 l Capacity Models 17 Frame Dimensions and Mounting Bolt Location For 30 lb 135 l and 35 lb 1...

Page 4: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 D1343...

Page 5: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT D1343 3...

Page 6: ...ble and combustible products Do not add the following substances or textiles containing traces of the following substances to the wash water gasoline kerosene waxes cooking oils vegetable oils machine...

Page 7: ...while the machine is running 16 Do not attach anything to the supply dispenser s nozzles if applicable The air gap must be maintained 17 Do not operate the machine without the water reuse plug or wate...

Page 8: ...parts to avoid safety hazards This machine must be installed adjusted and serviced by qualified electrical maintenance personnel familiar with the construction and operation of this type of machinery...

Page 9: ...HXN305P IS012 IS018 IS025 IS035 IS055 IS075 IS100 IS135 IS165 IXG060 IXG065 IXG075 IXG100 IXG135 IXG165 IXG235 IXG305 IXN060 IXN065 IXN075 IXN100 IXN135 IXN165 IXN235 IXN305 IXU060 IXU065 IXU075 IXU1...

Page 10: ...t Parts If literature or replacement parts are required contact the source from which the machine was purchased or contact Alliance Laundry Systems at 1 920 748 3950 for the name and address of the ne...

Page 11: ...8 kg 921 53 lb 418 kg 514 lb 233 kg 569 lb 258 kg Shipping weight 624 lb 283 kg 639 5 lb 290 kg N A N A 1030 lb 467 kg N A 624 lb 283 kg 639 5 lb 290 kg Shipping volume 22 5 ft3 0 8 m3 24 5 ft3 0 9 m3...

Page 12: ...0 1000 RPM 250 1000 RPM 250 1000 RPM 250 1000 RPM 250 1000 RPM Centrifugal Force Data Wash reverse centrifugal force 0 03 0 74 Gs 0 03 0 74 Gs 0 4 0 91 Gs 0 37 0 94 Gs 0 04 0 91 Gs 0 37 0 94 Gs 0 03 0...

Page 13: ...Electrical Steam Input 3 Hot Water Inlet 8 External Supply Signal Input 4 Cold Water Inlet 9 Electrical Power Input 5 Flushing Supply Dispenser 10 Drain Outlet 11 Steam Connection Output Figure 2 CFD...

Page 14: ...9 0 in 736 mm 29 0 in 736 mm 29 0 in 736 mm 29 0 in M 490 mm 19 3 in 490 mm 19 3 in 490 mm 19 3 in 490 mm 19 3 in N 660 mm 26 0 in 660 mm 26 0 in 660 mm 26 0 in 660 mm 26 0 in O 180 mm 7 1 in 180 mm 7...

Page 15: ...Direct Fill 7 Electrical Steam Input 3 Hot Water Inlet 8 External Supply Signal Input 4 Cold Water Inlet 9 Electrical Power Input 5 Flushing Supply Dispenser 10 Drain Outlet 11 Steam Connection Outpu...

Page 16: ...m 2 6 in J 1083 mm 42 6 in 1083 mm 42 6 in K 958 mm 37 7 in 958 mm 37 7 in L 898 mm 35 4 in 898 mm 35 4 in M 529 mm 20 8 in 529 mm 20 8 in N 780 mm 30 7 in 780 mm 30 7 in O 155 mm 6 1 in 155 mm 6 1 in...

Page 17: ...ets 2 Direct Fill 7 Electrical Steam Input 3 Hot Water Inlet 8 External Supply Signal Input 4 Cold Water Inlet 9 Electrical Power Input 5 Flushing Supply Dispenser 10 Drain Outlet 11 Steam Connection...

Page 18: ...2 in 81 mm 3 2 in I 81 mm 3 2 in 81 mm 3 2 in J 35 mm 1 4 in 35 mm 1 4 in K 830 mm 32 7 in 830 mm 32 7 in L 81 mm 3 2 in 81 mm 3 2 in M 959 mm 37 8 in 959 mm 37 8 in N 35 mm 1 4 in 35 mm 1 4 in O 92 9...

Page 19: ...600 mm 24 in 600 mm 24 in 600 mm 24 in 600 mm 24 in 600 mm 24 in 600 mm 24 in 600 mm Minimum clearance between machine and wall 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm...

Page 20: ...tion of the foundation Verify that the top of the foundation is level The height of the foundation and pad must not exceed 8 inches 203 mm above the existing floor IMPORTANT Mounting bolts MUST be use...

Page 21: ...0 AC diam 18 mm 0 71 in diam 18 mm 0 71 in diam 18 mm 0 71 in diam 18 mm 0 71 in AD 65 mm 2 6 in 65 mm 2 6 in 65 mm 2 6 in 65 mm 2 6 in AE 530 mm 20 9 in 530 mm 20 9 in 530 mm 20 9 in 530 mm 20 9 in A...

Page 22: ...ity Models Figure 6 Table 7 CFD637N Machine Capacity lb l 30 135 35 165 AC diam 18 mm 0 71 in diam 18 mm 0 71 in AD 66 mm 2 6 in 66 mm 2 6 in AE 648 mm 25 5 in 648 mm 25 5 in AF 780 mm 30 7 in 780 mm...

Page 23: ...41N Machine Capacity lb l 55 235 75 305 AA 81 mm 3 2 in 81 mm 3 2 in AB 738 mm 29 1 in 738 mm 29 1 in AC 900 mm 35 4 in 900 mm 35 4 in AD 81 mm 3 2 in 81 mm 3 2 in AE 35 mm 1 4 in 35 mm 1 4 in AF 830...

Page 24: ...e minimum 5 8 11 or 16 mm 4 To level machine fill the spaces between the machine base and floor with machinery grout Grout completely under all frame members Remove front and rear panels to gain acces...

Page 25: ...capacity models depending on model number to eliminate every possible movement of the tub After the machine has been placed level take off the service panels and the back panel to remove these transp...

Page 26: ...used when gravity drainage is not possible IMPORTANT Machine must be installed in accordance with all local codes and ordinances Before any deviation from specified installation procedures is attempt...

Page 27: ...le 9 Drain Line Sizing Minimum Drain ID Capacity lb l Number of Machines 1 2 3 4 5 6 7 12 60 2 in 51 mm 3 in 76 2 mm 3 5 in 88 mm 4 in 102 mm 4 5 in 114 mm 5 in 124 mm 5 5 in 140 mm 14 65 2 in 51 mm 3...

Page 28: ...et valves Pressure of 30 85 psi 2 5 7 bar provides best performance Although the machine will function at lower pressures increased fill times will occur with some loss of supply flushing Suitable air...

Page 29: ...elded in a liquid tight or approved flexible conduit with proper conductors of correct size installed in accordance with the National Electric Code or other applicable codes The connection must be mad...

Page 30: ...0 10 2 5 18 9 6Kw 240V X 200 240 50 60 1 3 2 3 PE 10 16 14 2 5 N A 18 75 C 380 415 50 60 3 3 N PE 10 16 14 2 5 16 2 9Kw 380V 20 10 2 5 18 8 9Kw 415V N 440 480 50 60 3 3 PE 4 1 6 14 2 5 14 3 9Kw 16 14...

Page 31: ...V 28 6 18Kw 380V 40 8 4 33 9 18Kw 415V Q 200 240 50 60 3 3 PE N A 40 18kW 208V 63 6 6 52 3 18Kw 240V X 200 240 50 60 1 3 2 3 PE 10 16 14 2 5 N A 55 235 C 380 415 50 60 3 3 N PE 16 20 14 2 5 31 4 18Kw...

Page 32: ...ing 200 240V 3AC 200 240V 3 phase 3AC should be connected to the connectors L1 L2 L3 Refer to Figure 12 The green yellow grounding clamp has to be connected to the grounding wire PE 380 415V 3AC N 380...

Page 33: ...13 A connection has been placed at the back of the machine There are five holes in this connection through each of which a liquid supply hose can be connected Dangerous Chemicals May damage eyes and s...

Page 34: ...nts are shown in Table 13 Steam Supply Information Steam inlet connection in mm 3 8 10 Number of steam inlets 1 Recommended pressure psi bar 30 80 2 0 5 5 Maximum pressure psi bar 80 5 5 Table 13 Neve...

Page 35: ...ply 5 on the WE 8 will activate supply relay 2 etc Programming supply 4 9 on the WE 8 will activate supply relay 1 6 on the board respectively Refer to Table 14 L1 220 VAC wire or terminal for remote...

Page 36: ...vendor will always use terminal 14 as the common terminal for all pumps This will apply for the remainder of the 220 VAC circuit for each of the pump signals For the remainder of the relays supply rel...

Page 37: ...tioning the probe should be centered horizontally and vertically at 1 3 from the bottom of the tilt window when machine drum is empty Automatic Lubricator Only for 75 lb 305 l Capacity Models Figure 2...

Page 38: ...door while a cycle is in progress The door should not open If the door lock and interlock are not functioning properly call a qualified service technician 7 For standard processing select Cycle 01 by...

Page 39: ...er to the applicable collection point for the recycling of electrical and electronic equipment Ensuring this product is disposed of correctly will help prevent potential negative consequences for the...

Page 40: ......

Page 41: ......

Page 42: ......

Reviews: