background image

Basic Installation/Operation

www.comlaundry.com

Washer-Extractors

Cabinet Freestanding

Part No. 9001014R7

June 2010

Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

Summary of Contents for UX100PV

Page 1: ...ation Operation www comlaundry com Washer Extractors Cabinet Freestanding Part No 9001014R7 June 2010 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine ...

Page 2: ......

Page 3: ...ents Introduction 2 Model Identification 2 Safety Information 3 Explanation of Safety Messages 3 Important Safety Instructions 3 Safety Decals 5 Operator Safety 6 Specifications and Dimensions 7 Installation 22 Dimensional Clearances 22 Machine Foundation 23 Mechanical Installation 24 Frame Dimensions and Mounting Bolt Location for 18 25 33 35 40 55 75 100 135 165 and 200 Models 24 Mounting Bolt I...

Page 4: ...ntroduction Model Identification Information in this manual is applicable to these models HX18PV HX100PV SX25PV SX135PV UX33PV UX100PV HX25PV HX135PV SX35PV SX165PV UX35PV UX135PV HX35PV HX165PV SX55PV SX200PV UX40PV UX165PV HX55PV HX200PV SX75PV UX18PV UX55PV UX200PV HX75PV SX18PV SX100PV UX25PV UX75PV ...

Page 5: ...r explosive substances to the wash water These substances give off vapors that could ignite or explode 5 Under certain conditions hydrogen gas may be produced in a hot water system that has not been used for two weeks or more HYDROGEN GAS IS EXPLOSIVE If the hot water system has not been used for such a period before using a washing machine or combination washer dryer turn on all hot water faucets...

Page 6: ...unless recommended by the manufacturer of the fabric softener or product 19 Keep washer in good condition Bumping or dropping the washer can damage safety features If this occurs have washer checked by a qualified service person 20 If the supply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent 21 Be sure water connections have a...

Page 7: ...be installed adjusted and serviced by qualified electrical maintenance personnel familiar with the construction and operation of this type of machinery They must also be familiar with the potential hazards involved Failure to observe this warning may result in personal injury and or equipment damage and may void the warranty SW004 WARNING Install the machine on a level floor of sufficient strength...

Page 8: ...th the door unlocked c Close and lock the door and start a cycle Attempt to open the door while the cycle is in progress The door should not open If the door lock and interlock are not functioning properly call a service technician 3 Do not attempt to operate the machine if any of the following conditions are present a The door does not remain securely locked during the entire cycle b Excessively ...

Page 9: ...01 lb Net weight 236 kg 520 lb 241 kg 531 lb N A 347 kg 765 lb N A Shipping weight 233 kg 514 lb 258 kg 569 lb 383 kg 844 37 lb 388 kg 855 lb 418 kg 921 53 lb Shipping weight 283 kg 624 lb 290 kg 639 5 lb N A 467 kg 1030 lb N A Shipping volume 0 8 m3 22 5 ft 3 0 9 m3 24 5 ft 3 1 21 m3 42 83 ft 3 1 3 m3 34 7 ft 3 1 3 m3 45 98 ft 3 Wash Cylinder Information Cylinder diameter 530 mm 20 9 in 530 mm 20...

Page 10: ...0 1000 RPM 250 1000 RPM 250 1000 RPM 250 1000 RPM Centrifugal Force Data Wash reverse centrifugal force 0 03 0 74 Gs 0 03 0 74 Gs 0 37 0 94 Gs 0 04 0 91 Gs 0 37 0 94 Gs Extract centrifugal force 19 296 Gs 19 296 Gs 24 377 Gs 23 363 Gs 24 377 Gs Balance Detection Vibration safety switch installed Standard Standard Standard Standard Standard Direct Steam Heating Optional Steam inlet connection size ...

Page 11: ...97 kg 3741 lb 1822 kg 4017 lb 2319 kg 5113 lb 3000 kg 6613 86 lb Shipping volume 1 5 m3 54 9 ft 3 2 1 m3 74 ft 3 3 3 m3 115 ft 3 3 7 m3 131 ft 3 4 4 m3 162 ft 3 6 17 m3 217 89 ft 3 Wash Cylinder Information Cylinder diameter 750 mm 29 5 in 850 mm 33 5 in 980 mm 38 6 in 980 mm 38 6 in 1095 mm 43 1 in 1095 mm 43 1 in Cylinder depth 530 mm 20 9 in 537 mm 21 1 in 597 mm 23 5 in 775 mm 30 5 in 775 mm 3...

Page 12: ... RPM 250 800 RPM 250 750 RPM 250 750 RPM Centrifugal Force Data Wash reverse centrifugal force 0 04 1 05 Gs 0 05 1 19 Gs 0 06 1 37 Gs 0 06 1 37 Gs 0 06 1 52 Gs 0 06 1 52 Gs Extract centrifugal force 26 418 Gs 30 475 Gs 34 350 Gs 34 350 Gs 34 344 Gs 34 342 Gs Balance Detection Vibration safety switch installed Standard Standard Standard Standard Standard Standard Direct Steam Heating Optional Steam...

Page 13: ...ng Supply Dispenser 10 Steam Connection Input Optional Figure 1 CFD530 N CFS464N CFS465N 18 AND 25 POUND CAPACITY MODELS WITH U IN THE 8TH POSITION E G X18PVXU6 1031 mm 40 6 in 518 mm 20 4 in 660 mm 26 in CFD530N CFS464N CFS465N 229 mm 9 in 152 mm 6 in 74 mm 2 9 in 140 mm 5 5 in 780 mm 30 7 in 742 mm 29 2 in 41 mm 1 6 in 389 mm 15 3 in 158 mm 6 2 in 51 mm 2 in 181 mm 7 1 in 1 4 6 3 2 10 279 mm 11 ...

Page 14: ...8 mm 40 87 in 1011 mm 39 8 in 279 mm 10 98 in 530 mm 20 87 in 65 mm 2 56 in 660 mm 25 98 in 65 mm 2 56 in 887 mm 34 92 in 791 mm 31 14in 485 mm 19 1 in 70 mm 2 76 in 44 mm 1 73 in 180 mm 7 09 in 660 mm 25 98 in 11 10 4 2 1 9 33 mm 1 3 in 18 590 mm 23 23 in 25 690 mm 27 16 in 747 mm 29 41 in 8 3 33 mm 1 3 in 30 mm 1 18 in 220 mm 8 66 in 7 CFD521N 18 670 mm 26 38 in 25 770 mm 30 31 in 18 727 mm 28 6...

Page 15: ...nection Input Optional Figure 3 CFD539N CFD539N CFD537N CFD538N 1376 mm 54 15 in 1348 mm 53 07 in 472 mm 18 58 in 680 mm 26 77 in 50 mm 1 97 in 780 mm 30 71 in 50 mm 1 97 in 1141 mm 44 9 in 1108 mm 43 6 in 704 mm 27 7 in 185 mm 7 29 in 170 mm 6 69 in 3 2 1 10 665 mm 26 18 in 1066 mm 41 95 in 9 4 86 5 mm 3 41 in 220 mm 8 66 in 7 CFD537N 34 mm 1 34 in 1015 mm 39 96 in 1 38 in 35 mm 332 mm 13 05 in 2...

Page 16: ...uired 9 Drain Outlet 5 Flushing Supply Dispenser 10 Steam Connection Input Optional Figure 4 CFD531N CFS467N CFD531N CFS467N 1194 mm 47 in 620 mm 24 4 in 782 mm 30 8 in CFS468N 328 mm 12 9 in 264 mm 10 4 in 934 mm 36 75 in 960 mm 37 8 in 155 mm 6 1 in 889 mm 35 in 203 mm 8 in 1001 mm 39 4 in 112 mm 4 4 in 394 mm 15 5 in 5 508 mm 20 in 965 mm 38 in 1041 mm 41 in 89 mm 3 5 in 1 3 2 4 8 7 9 10 6 639 ...

Page 17: ...FD525N CFD529N CFD524N CFD525N 1202 mm 47 32 in 1176 mm 46 3 in 66 mm 2 6 in CFD529N 34 mm 1 34 in 267 mm 10 49 in 893 mm 35 16 in 88 mm 3 47 in 332 mm 13 05 in 530 mm 20 87 in 200 mm 7 87 in 70 mm 2 76 in 843 mm 33 17 in 376 mm 14 78 in 11 60 mm 2 36 in 935 mm 36 81 in 968 mm 38 11 in 202 mm 7 93 in 1 3 2 4 7 9 10 6 648 mm 25 51 in 36 5 mm 1 44 in 35 POUND CAPACITY MODELS WITH A OR M IN THE 8TH P...

Page 18: ...nection Input Optional Figure 6 CFD539N CFD539N CFD537N CFD538N 1376 mm 54 15 in 1348 mm 53 07 in 472 mm 18 58 in 680 mm 26 77 in 50 mm 1 97 in 780 mm 30 71 in 50 mm 1 97 in 1141 mm 44 9 in 1108 mm 43 6 in 704 mm 27 7 in 185 mm 7 29 in 170 mm 6 69 in 3 2 1 10 765 mm 30 12 in 1066 mm 41 95 in 9 4 86 5 mm 3 41 in 220 mm 8 66 in 7 CFD537N 34 mm 1 34 in 1015 mm 39 96 in 35 mm 1 38 in 332 mm 13 05 in 2...

Page 19: ...utlet Optional 5 Flushing Supply Dispenser 11 Steam Connection Input Optional 6 External Liquid Supply Inlets CFD509N CFS470N 61 CFD509N 1544 mm 60 8 in 859 mm 33 8 in 900 mm 35 43 in 1499 mm 59 in CFS470N 1016 mm 40 in CFS471N 55 MODEL 158 mm 6 2 in 254 mm 10 in 91 mm 13 6 in 99 mm 3 9 in 191 mm 7 5 in 165 mm 6 5 in 104 mm 4 1 in 1389 mm 54 7 in 721 mm 28 4 in 36 mm 1 4 in 1 3 4 9 11 559 mm 22 in...

Page 20: ...ain Outlet Optional 5 Flushing Supply Dispenser 11 Steam Connection Input Optional 6 External Liquid Supply Inlets 61 CFD510N CFS473N CFD510N 1575 mm 62 in 853 mm 33 6 in 1532 mm 60 3 in 1168 mm 46 in CFS473N CFS474N 75 MODEL 229 mm 9 in 488 mm 19 2 in 94 mm 3 7 in 175 mm 6 9 in 170 mm 6 7 in 104 mm 4 1 in 1407 mm 55 4 in 582 mm 22 9 in 43 mm 1 7 in 2 3 4 9 11 5 102 mm 4 in 559 mm 22 in 1060 mm 41...

Page 21: ...t Optional 6 Flushing Supply Dispenser 13 Service Power Disconnect 7 External Liquid Supply Inlets CFD511N CFS476N CFD511N 1951 mm 76 8 in 960 mm 37 8 in 1040 mm 40 94 in 1200 mm 47 24 in CFS476N 100 1331 mm 52 4 in 135 1506 mm 59 3 in CFS477N 305 mm 12 in 2362 mm 9 3 in 175 mm 6 9 in 104 mm 4 1 in 114 mm 4 5 in 165 mm 6 5 in 221 mm 8 7 in 170 mm 6 7 in 51 mm 2 in 249 mm 9 8 in 696 mm 27 4 in 216 ...

Page 22: ...red 12 Steam Connection Input Optional 6 Flushing Supply Dispenser 13 Service Power Disconnect 7 External Liquid Supply Inlets CFD511N CFD511N 2100 mm 82 7 in 1020 mm 40 2 in 1140 mm 44 9 in 1300 mm 51 2 in CFS477N 360 mm 14 25 in 273 mm 10 75 in 198 mm 7 8 in 114 mm 4 5 in 114 mm 4 5 in 172 mm 6 75 in 221 mm 8 7 in 197 mm 7 75 in 51 mm 2 in 260 mm 10 24 in 696 mm 27 4 in 254 mm 10 in 6 641 mm 25 ...

Page 23: ...vice Power Disconnect 7 External Liquid Supply Inlets Figure 11 CFD533N CFD533N 2100 mm 82 7 in 993 mm 39 in 1138 mm 44 8 in CFD535N 81 mm 3 19 in 1300 mm 51 18 in 323 mm 12 72 in 248 mm 9 76 in 257 mm 10 12 in 486 mm 19 13 in 899 5 mm 35 37 in 6 603 mm 23 75 in 408 mm 16 06 in 12 2 3 5 4 1 9 13 8 10 11 7 CFD534N CFD534N 44 mm 1 73 in 175 2 mm 68 96 in 260 mm 10 24 in 260 mm 10 24 in 81 mm 3 19 in...

Page 24: ...4 in 600 mm 24 in 600 mm 24 in 600 mm 24 in 600 mm 24 in Minimum clearance between machine and wall 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in 150 mm 6 in Minimum clearance between machines side 25 4 mm 1 in 25 4 mm 1 in 30 mm 1 2 in 25 4 mm 1 in 30 mm 1 2 in 30 mm 1 2 in 30 mm 1 2 in 30 mm 1 2 in 30 mm 1 2 in 30 mm 1 2 i...

Page 25: ...unless mandated by state or local codes Static and dynamic loads on the floor or foundation are shown in Table 2 Table 2 can be used as a reference when designing floors and foundations Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided Never allow the inspection and maintenance space to be bl...

Page 26: ...38 in 55 mm 2 17 in 486 mm 19 13 in 87 mm 3 43 in 55 mm 2 17 in 87 mm 3 43 in CFS478N 660 mm 26 in 660 mm 25 98 in 87 mm 3 43 in 55 mm 2 17 in 770 mm 30 31 in 87 mm 3 43 in 486 mm 19 13 in 55 mm 2 17 in 25 MODEL CFD541N Figure 14 CFS480N CFD541N 34 mm 1 34 in 665 mm 25 18 in 680 mm 26 77 in 50 mm 1 97 in 733 mm 28 86 in 50 mm 1 97 in 780 mm 30 71 in 22 mm 87 in 33 MODEL 34 mm 1 34 in CFS480N 35 MO...

Page 27: ...in 22 mm 0 87 in 40 MODEL 34 mm 1 34 in CFS481N 55 MODEL 898 mm 35 35 in 830 mm 32 68 in 930 mm 36 61 in 740 mm 29 13 in 80 mm 3 15 in 50 mm 1 97 in 50 mm 1 97 in 80 mm 3 15 in CFS483N CFS482N CFS483N 75 MODEL 1060 mm 41 73 in 1080 mm 42 52 in 95 mm 3 74 in 960 mm 37 8 in 60 mm 2 36 in 870 mm 34 25 in 60 mm 2 36 in 95 mm 3 74 in CFS482N 100 MODEL 1200 mm 47 24 in 1090 mm 42 91 in 80 mm 3 15 in 101...

Page 28: ... 1185 mm 46 65 in 80 mm 3 15 in 1040 mm 40 94 in 80 mm 3 15 in 42 5 mm 1 67 in 42 5 mm 1 67 in 165 MODEL 1300 mm 51 2 in 1251 mm 49 25 in 80 mm 3 15 in 80 mm 3 15 in 1185 mm 46 7 in 1140 mm 44 9 in 33 mm 1 3 in 33 mm 1 3 in CFd536N Figure 22 CFD536N 44 mm 1 73 in 1300 mm 51 18 in 61 mm 3 19 in 44 mm 1 73 in 61 mm 3 19 in 1138 mm 44 8 in 1300 mm 51 18 in 200 MODEL 1135 mm 44 8 in ...

Page 29: ...of the bolt must be minimum 5 8 11 or 16 mm 4 To level machine fill the spaces between the machine base and floor with machinery grout Grout completely under all frame members Remove front and rear panels to gain access to all frame members Force grout under the machine base until all voids are filled 5 Remove the spacers carefully allowing the machine to settle into the wet grout 6 Position washe...

Page 30: ...15 50 60 3 3 N PE Not available 36 40 8 10 0 Q 200 240 50 60 3 3 PE Not available 58 60 6 16 0 X 200 240 50 60 1 3 2 3 PE 12 15 14 2 5 Not available 40 N 440 480 50 60 3 3 PE 6 15 14 2 5 32 40 8 10 0 P 380 415 50 60 3 3 N PE 18 20 12 4 0 44 50 8 10 0 Q 200 240 50 60 3 3 PE 18 20 12 4 0 63 70 4 25 0 X 200 240 50 60 1 3 2 3 PE 18 20 12 4 0 Not available 55 N 440 480 50 60 3 3 PE 12 15 14 2 5 41 50 8...

Page 31: ...pecifications Voltage Designation Standard Electric Heat Model Code Voltage Cycle Phase Wire Full Load Amps Circuit Breaker AWG mm 2 Full Load Amps Circuit Breaker AWG mm 2 200 N 440 480 50 60 3 3 PE 19 25 10 6 0 Not available P 380 415 50 60 3 3 N PE 18 25 10 6 0 Not available Q 200 240 50 60 3 3 PE 27 40 8 10 0 Not available Table 3 ...

Page 32: ...lliance Laundry Systems LLC DO NOT COPY or TRANSMIT Basic Installation Operation 9001014 30 Operation Control Identification Figure 24 1 Keypad 4 Key Switch 2 Display 5 Serial Port 3 Emergency Stop Button 3 1 5 4 2 ...

Page 33: ...ou to open the door NOTE Some models may have a door handle with a button that must be pressed 2 Load the drum to the specified capacity 3 Close the door by pushing the door handle towards the machine For models 100PV 200PV 1 Push on the doorlock system to open the door 2 Load the drum to the specified capacity 3 Close the door by pushing the door handle towards the machine ...

Page 34: ...hall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Ensuring this product is disposed of correctly will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For mor...