40
F238006
Section 4 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
A-B 1336 Control Logic
H – Control Voltage High 5 Volts DC
Logic 0
L – Control Voltage Low <1 Volt DC
Logic 1
Voltage Reading Pos (+) Volts DC
27
28
26
22
20
19
Input Status Parameter #55
Voltage Reading Neg (-) Volts DC
29
29
29
29
29
29
V Computer
Action
A-B 1336
Frequency
Preset
Parameter
Preset
#
Preset
Input/
SW2
Preset
Input/
SW1
Preset
Input/
SW3
Reverse
Motion/
STR
Stop
Forward
Motion/
STF
SW2
SW1
SW3
M
T
R TEMP
STR
N/
A
ST
OP
STF
Half Wash Fwd
73
4
H
H
L
H
L
L
0
0
1
1
0
0
1
1
Half Wash Rev
73
4
H
H
L
L
L
H
0
0
1
1
1
0
1
0
Wash Fwd
28
2
L
H
H
H
L
L
1
0
0
1
0
0
1
1
Wash Rev
28
2
L
H
H
L
L
H
1
0
0
1
1
0
1
0
Distribution
27
1
H
L
H
H
L
L
0
1
0
1
0
0
1
1
Spin 1
75
6
L
H
L
H
L
L
1
0
1
1
0
0
1
1
Spin 2
29
3
L
L
H
H
L
L
1
1
0
1
0
0
1
1
Spin 3
74
5
H
L
L
H
L
L
0
1
1
1
0
0
1
1
WE-6 Controller
Half Wash Fwd
73
4
H
H
L
H
L
L
0
0
1
1
0
0
1
1
Half Wash Rev
73
4
H
H
L
L
L
H
0
0
1
1
1
0
1
0
Wash Fwd
28
2
L
H
H
H
L
L
1
0
0
1
0
0
1
1
Wash Rev
28
2
L
H
H
L
L
H
1
0
0
1
1
0
1
0
Distribution
27
1
H
L
H
H
L
L
0
1
0
1
0
0
1
1
Med. Spin
75
6
L
H
L
H
L
L
1
0
1
1
0
0
1
1
High Spin 1
74
5
H
L
L
H
L
L
0
1
1
1
0
0
1
1
High Spin 2
29
3
L
L
H
H
L
L
1
1
0
1
0
0
1
1
High Spin 3
76
7
L
L
L
H
L
L
1
1
1
1
0
0
1
1