background image

Programming

Washer-Extractor

Refer to Page 7 for Model Numbers

CHM1311R_SVG

Original Instructions
Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

www.alliancelaundry.com

Part No. F8237801ENR13

March 2017

Summary of Contents for UCN020HN2

Page 1: ...to Page 7 for Model Numbers CHM1311R_SVG Original Instructions Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine www alliancelaundry co...

Page 2: ......

Page 3: ...of this type of machinery They must also be familiar with the potential hazards involved Failure to observe this warning may result in personal injury property damage and or equip ment damage and wil...

Page 4: ...art Mode 12 End of Cycle Mode 12 Cycle Sequence 12 Run Mode 12 Signals 12 Changing Cycles 12 Door Unlocking Mode 12 Special Features 13 Programming the Control 13 Collecting Audit Information 13 Testi...

Page 5: ...H 35 Warm Water Temperature FHC 35 Cold Water Temperature FC 36 Cooldown Enable Temperature Codn 36 Production Test Cycle Enable Disable PtEn 37 Manual Rapid Advance Enable Disable rAEn 37 No Cycle Ti...

Page 6: ...50 How to Exit Rapid Advance Feature 50 Communications Mode 51 Infra red Communications 51 How to Begin Communications with an External Device 51 Default Cycles 52 Copyright Alliance Laundry Systems L...

Page 7: ...NF HCU040HNV ICN040HNF ICN040HNV SCB040HNF SCB040HNV SCL040HN2 SCL040HNF SCL040HNV SCN040HN2 SCN040HNF SCN040HNV SCU040HN2 SCU040HNF UCB040HNF UCB040HNV UCH040HNF UCH040HNV UCL040HN2 UCL040HNF UCL040H...

Page 8: ...or the name and address of the nearest authorized parts distributor Customer Service For technical assistance contact your local distributor or contact Alliance Laundry Systems Shepard Street P O Box...

Page 9: ...area of the control that displays words and values LED Light Emitting Diode This term refers to the lights next to the keypads and status words of the control Power Failure Recovery If a cycle is in...

Page 10: ...and the cycle will begin The Select Cycle keypads are used in various combinations for programming cycles retrieving audit information running diag nostic tests and other operations These instructions...

Page 11: ...rinse is complete SPIN LED Spin LED is lit during the final spin portion of the cycle DOOR LED Door LED is lit whenever the door is locked The door can t be opened when this LED is lit BLEACH LED Blea...

Page 12: ...EDs will light while the machine passes through different cycle steps Any coin entered after the first fill step will be added to the total coin counter but the user will not be able to change cycles...

Page 13: ...Type Design 2 and 3 models only For detailed information on running diagnostic tests refer to Test ing Machine and Electronic Control Functions Rapid Advance Feature This feature allows the user to q...

Page 14: ...3 Lift the top cover up To completely remove lift top cover away from both top cover hinges Refer to Figure 2 After removing or opening and closing the top cover the opera tor has 4 minutes and 15 se...

Page 15: ...th an external de vice Refer to the appropriate instruction manual Manual Rapid Advance can be turned on and off using an external device or by manual programming refer to Manual Rapid Advance Enable...

Page 16: ...through cycle steps Press the START enter keypad to enter Manual Programming Refer to Manual Programming flowchart CyC Total machine cycles Press the START keypad Press the START enter keypad to rese...

Page 17: ...codes in the Option Display column of Table 1 are what will show in the display when that option is selected Programmable Options Available Option Number Option Dis play Description Default Value Val...

Page 18: ...penser Program ming is programmed Design 2 and 3 models Compartment and Supply dispensing is programmed separately Press START enter key pad to access options 1 C2 orS1 Compartment 2 Supply 1 Design 1...

Page 19: ...if heater is present oFF 1 2 5 drAn Drain Step a SPEn Extract Step Enable Disable on oFF b SSEC Extract Seconds 0 59 c SnIn Extract Minutes Intermediate Extract Min Step Time 30 sec onds Max Step Tim...

Page 20: ...mperature 35 F 2 C 35 F 194 F 2 C 90 C 12 Codn Cooldown Enable Tempera ture oFF oFF 50 F 160 F 10 C 71 C 13 PtEn Production Test Cycle Ena ble Disable on on oFF 14 rAEn Manual Rapid Advance Enable Dis...

Page 21: ...st Cy Program aspects for the various steps in each type of cycle There are 9 cycles available for programming tyPE Agitation Type 1 18 3 18 2 3 12 3 SEg1 Program Options for each Segment There are 8...

Page 22: ...tep SPIn Program Extract Step Options Drain Step Enable Disable on Enable oFF Disable S4 Supply 4 on Enabled oFF Disabled C2 or S1 Compartment 2 Supply 1 on Enabled oFF Disabled Design 1 Models C3 or...

Page 23: ...bled oFF Disabled rAEn Enable disable the rapid advance feature on Enabled oFF Disabled nCtd Enable disable whether the cycle time will appear in display on Enabled oFF Disabled bALr VFD only Program...

Page 24: ...ht Test bAL Design 1 Models d021 Water Leak Detection Test Ld d020 VFD Balance Water Purge Test PUrg d019 Drive DC Bus Display Test dCb Design 2 and 3 Models d023 Drive Parameter Table Version Number...

Page 25: ...the current number to the desired number Refer to Table 2 5 Press the START enter keypad when the correct number ap pears in the display The next option AUd will appear in the display NOTE To program...

Page 26: ...d turn off all the options except KEYPAD In this instance the sig nal would sound only when a keypad is pressed 7 Press the START enter keypad when the correct number ap pears in the display The next...

Page 27: ...OFF ON 18 ON OFF OFF ON OFF 19 ON OFF OFF ON ON 20 ON OFF ON OFF OFF 21 ON OFF ON OFF ON 22 ON OFF ON ON OFF 23 ON OFF ON ON ON 24 ON ON OFF OFF OFF 25 ON ON OFF OFF ON 26 ON ON OFF ON OFF 27 ON ON OF...

Page 28: ...Programming CyC To program other options refer to the appropriate section Error Parameters E FL Fill Error E dr Drain Error E Ub Unbalance Error Display VFD models on ly E oP Open Thermistor Error Di...

Page 29: ...tyPE Agitate Type 1 18 3 18 Agita tion Action 2 3 12 3 Agitation Action Table 5 continues Final Spin Step Description Status ASPd Agitate Speed VFD only Lo Reduced Speed rEg Normal Speed Table 5 5 Pr...

Page 30: ...6 keypad to change the current status 5 Press the START enter keypad when the desired status ap pears in the display The next Fill step option will appear in the display NOTE To program SUPL Supply St...

Page 31: ...he display 2 Press the 3 or the 6 keypad to scroll through the pro grammable Agitate step options Refer to Table 8 NOTE Agitate Step AgEn must be enabled to scroll through all Agitate Step options 3 P...

Page 32: ...er keypad when the desired status value appears in the display The next Cycle Segment step option SEg2 will appear in the display NOTE To program Cnin Cycle Time continue to next Cycle Segment option...

Page 33: ...ll appear in the display 3 Press the 3 or the 6 keypad to scroll through the pro grammable options until bALr appears in the display 4 When bALr appears in the display press the START enter keypad The...

Page 34: ...e START enter keypad A number will appear in the display This number corresponds to the current Fahrenheit Celsius setting CEL Celsius FAHr Fahrenheit default setting 5 Press the 3 or the 6 keypad to...

Page 35: ...er options refer to the appropriate section Warm Water Temperature FHC This option allows the owner to program the warm water temper ature for models equipped with heat 1 Control must be in Manual Mod...

Page 36: ...o program other options refer to the appropriate sec tion Cooldown Enable Temperature Codn This option allows the owner to enable or disable the Cooldown Water Temperature option If enabled the owner...

Page 37: ...le rAEn To program other options refer to the appropriate section Manual Rapid Advance Enable Disable rAEn This option allows the owner to enable or disable the rapid ad vance feature Refer to Rapid A...

Page 38: ...his option allows the owner to program the displayed cycle time 1 Control must be in Manual Mode Refer to Entering the Man ual Mode 2 Press the 3 or the 6 keypad until Prog appears in the display Pres...

Page 39: ...the display 4 When SdAd appears in the display press the START enter keypad The current Slow Drain Detection Adjust value will appear in the display on Option Enabled oFF Option Disabled default setti...

Page 40: ...2 Once the desired option appears in the display press the START enter keypad once 1 to start the audit count At this point the display will show the first four 4 digit seg ment of the audit value If...

Page 41: ...amming Control How to Enter Manual Reset 1 Control must be in Manual Mode Refer to Entering the Man ual Mode 2 Press the 3 or the 6 keypad until rSEt appears 3 Press the START enter keypad The control...

Page 42: ...the di agnostic test options How to Start Tests To start a diagnostic test refer to the quick reference chart Table 11 Press the START enter keypad when the desired test num ber is displayed For detai...

Page 43: ...will end return to Water Purge Test start prompt and door will unlock if any keypad is pressed the door is unlocked or opened if an end test communication is received or if two 2 mi nutes has occurre...

Page 44: ...ostic Testing Mode Production Test Cycle NOTE Machine should be empty of water before start ing Production Test Cycle To Enter Production Test Cycle 1 Be certain control is in Ready Mode and top cover...

Page 45: ...Level reached CFIL Cold Fill to Low Level All water outputs turned off when Low Level reached bFIL Warm Fill to Low Level All water outputs turned off when Low Level reached bFIH Warm Fill to High Lev...

Page 46: ...els SP 2 Extract Speed 2 low This step skipped on 2 speed models SP 3 Extract Speed 3 medium This step skipped on 2 speed models SP 4 VFD models or SPIn 2 speed models Extract Speed 4 high Design 2 an...

Page 47: ...tion Error Communication error Re aim external device and try again If the problem persists check that the security code is correct EI0F Infra red Disabled Communication failure or infra red is disabl...

Page 48: ...ly after the test until the machine is pow ered down to clear the error E LF Water Leak Detection Error Control senses an increase in water level during diagnostic test ing Power down machine to clear...

Page 49: ...erify convection around drive heat sink power up and try again Ed07 No Setup Error The drive receives movement commands without receiving a set up packet Power down power up and try again Ed08 Max Ove...

Page 50: ...is in For Example If the machine is in the first Fill cycle step press ing the START enter keypad will advance the machine into the Agitate cycle step Continue pressing the START enter keypad until th...

Page 51: ...th an External Device The control will go blank and the display will show C until the communication is complete If an error occurs that terminates communication the display will show EIxx xx represent...

Page 52: ...l Temperature Hot Hot Warm Warm Warm Warm Warm Warm Cold Fill Level Low Low High High High High High High High Supply C1 C2 C3 S1 S2 C1 C2 C3 S1 S2 C1 C1 C1 C1 C1 C1 C1 C2 S1 Heat if enabled 2 2 2 2 2...

Page 53: ...Low Low Low Low Low High High Low Supply C1 C2 C3 C1 C2 C3 C1 C2 C3 S2 C1 C2 C3 S2 C1 C2 C3 S2 C1 C2 C3 S2 C1 C2 C3 S2 C1 C2 C3 S2 C1 C2 Heat if enabled 2 2 2 2 2 2 2 2 2 Drain Yes Yes Yes Yes Yes Ye...

Page 54: ...1 C2 Heat if enabled 0 0 0 0 0 0 0 0 0 Drain Yes Yes Yes Yes Yes Yes Yes Yes Yes Spin min 0 0 0 0 0 0 0 0 0 Rinse 2 ON OFF ON ON ON ON ON ON ON ON OFF Time for agitation min 2 2 2 2 2 2 2 2 2 Fill Tem...

Page 55: ...agitation min 4 4 4 5 4 5 4 4 4 Fill Temperature Warm Warm Warm Warm Warm Warm Warm Warm Cold Fill Level Low Low Low Low Low Low Low Low High Supply C1 C2 C3 C4 S3 S4 C1 C2 C3 C4 S3 S4 C1 C2 C3 C4 S3...

Page 56: ...29 50 00 30 50 00 41 50 00 43 50 00 42 50 00 44 50 00 44 50 00 55 50 00 26 05 F and V speed Design 2 and 3 00 30 02 00 31 02 00 44 02 00 44 02 00 43 02 00 45 02 00 44 02 00 56 02 00 25 32 Table 16 Int...

Page 57: ...S1 S2 C1 C2 C3 S1 S2 C1 C2 C3 S1 S2 C1 C2 C3 S1 S2 C1 C2 C3 S1 S2 Heat if enabled 2 2 2 2 2 2 2 2 2 Drain Yes Yes Yes Yes Yes Yes Yes Yes Yes Spin min 0 0 0 0 0 0 0 0 0 Wash 3 ON OFF OFF OFF OFF OFF O...

Page 58: ...l Level High High High High High High High High High Supply C1 C2 C3 C1 C2 C3 C1 C2 C3 C1 C2 C3 C1 C2 C3 C1 C2 C3 C1 C2 C3 C1 C2 C3 C1 C2 C3 Heat if enabled 0 0 0 0 0 0 0 0 0 Drain Yes Yes Yes Yes Yes...

Page 59: ...n min 3 3 3 3 3 3 3 3 3 Fill Temperature Cold Cold Cold Cold Cold Cold Cold Cold Cold Fill Level High High High High High High High High High Supply C1 C2 C3 C4 S3 S4 C1 C2 C3 C4 S3 S4 C1 C2 C3 C4 S3...

Page 60: ...33 02 00 33 02 00 31 02 00 31 02 00 31 02 00 31 02 00 29 32 00 25 32 Table 17 Blank Cycle Chart Cycle Steps Perm Press Light Soil Cot ton Terry Light Soil Perm Press Medi um Soil Cot ton Terry Medi u...

Page 61: ...3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Heat if enabled Drain Spin min Wash 2 ON OFF Time for...

Page 62: ...or mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Time for agitation min Fill Temperature Fill Level Supply He...

Page 63: ...pe 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Heat if enabled Drain Spin min Rinse 3 ON OFF T...

Page 64: ...Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Default Cycle Time hh mm s s 2 speed F and V speed Design 1...

Page 65: ...3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Heat if enabled Drain Spin min Wash 3 ON OFF Time for...

Page 66: ...or mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Time for agitation min Fill Temperature Fill Level Supply He...

Page 67: ...Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Heat if enabled Drain Spin min Rinse 4 ON OFF Time for agi...

Page 68: ...8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Fill Temperature Fill Level Supply Heat if enabled Drain...

Page 69: ...ype 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Drain Spin min Wash 4 ON OFF Time for agitatio...

Page 70: ...or mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Time for agitation min Fill Temperature Fill Level Supply He...

Page 71: ...8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Heat if enabled Drain Spin min Default Cycle Time hh mm s...

Page 72: ...8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Fill Temperature Fill Level Supply Heat if enabled Drain...

Page 73: ...ype 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Drain Spin min Rinse 1 ON OFF Time for agitati...

Page 74: ...CYC8 CYC9 Agitation type 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 3 12 3 Gentle Time for agitation min F...

Page 75: ...splay in Pro gram Mode CYC1 CYC2 CYC3 CYC4 CYC5 CYC6 CYC7 CYC8 CYC9 Agitation type 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor mal 18 3 1 8 Nor ma...

Reviews: