Troubleshooting
7. No Agitation
No agitation.
Is timer
inoperative?
Test for
continuity
through timer
circuits (refer to
wiring diagram)
and replace if
inoperative.
Yes
Motor
won't run?
Refer to
Test
Procedures
section
to check switch
and windings.
Yes
Is pressure
switch
inoperative?
Test switch. Must
have continuity
from terminal 1 to
3. Replace if
inoperative.
TLW358S
Has drive
motor overload
protector
cycled?
Wait two or three
minutes for
overload protector
to reset. If
protector cycles
repeatedly, refer
to
Paragraph 9
.
Yes
Is there a
bind in
pump?
Replace pump.
Yes
Close lid or test
switch and
replace if
inoperative.
Yes
Is there
broken, loose
or incorrect
wiring?
Refer to
appropriate
wiring diagram.
Yes
Is lid open
or lid switch
inoperative?
No
Yes
Is transmission
assembly
inoperative?
Repair or
replace
transmission
assembly.
Yes
Is drive belt
broken or
loose?
Replace belt.
Yes
Are pauses
part of
normal cycle?
Timer is
designed to
pause (SOAK)
during
DELICATE
cycle. Allow
completion of
SOAK period.
Yes
No delicate
cycle
agitate?
Refer to
Test
Procedures
section to check
low speed switch
and windings.
No
No
No
Yes
No
No
Is motor pulley
roll pin sheared
(through Serial
No. 001113645)?
Remove drive
motor and
replace roll pin
and any other
damaged
parts.
No
Yes
No
No
No
No