39311
29
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
22. Mixing Valve Solenoid Test Procedure
Mixing valve test procedures using an Ohm meter.
NOTE: Resistance readings slightly out of given ranges may be due to meter conditions. These readings DO
NOT necessarily indicate mixing valve failure.
23. Temperature Switch Test Procedure
Check for continuity between the following terminal connections:
120 Volt coils
900 - 1100 Ohms
3 Position Switches
Temperature
Connection
Wash
Rinse
Hot
Cold
L - 3
Warm
Cold
L - 3- 4
Cold
Cold
L - 4
4 Position Switches
Temperature
Connection
Wash
Rinse
Hot
Cold
L1 - 2
Warm
Warm
L1 - 1, L1 - 2, L2 - 2, L2 - 1,
L2 - L1, 1 - 2
Warm
Cold
L1 - 2, L1 - 1, 1 - 2
Cold
Cold
L1 - 1
5 Position Switches
Temperature
Connection
Wash
Rinse
Hot
Cold
L1 - 2
Hot
Warm
L1 - 2, L2 - 2
Warm
Cold
L1 - 1, L1 - 2
Warm
Warm
L1 - 1, L1 - 2, L2 - 2
Cold
Cold
L1 - 1
Summary of Contents for LWS01M series