Section 5
Test Procedures
21. Motor Test Procedure
IMPORTANT: Disconnect base wire harness plug from motor.
Motor test procedures using an Ohm meter.
NOTE: Resistance readings slightly out of given ranges may be due to meter conditions. These readings DO
NOT necessarily indicate motor failure.
NOTE: Steps 8, 9 and 10 are with motor centrifugal mechanism in the run position.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
WARNING
Disconnect electric power to washer before performing the following steps:
W188
Meter Connections
Reading
Should Be
If Not
1.
Ground to Each Other Terminal
Open
Terminal shorted to ground.
2.
White to Yellow
Closed
Open thermal overload.
3.
Red to Brown
2-8 Ohms
Start winding open or resistance too high or too
low.
4.
Blue to White
1-2 Ohms
High speed winding (4 pole) open or resistance
too high or too low.
5.
Violet to White (2-speed motor)
2.5 Ohms
(Approximate)
Low winding opening; High speed winding open;
or resistance too high or too low.
6.
“R” to Red
Closed
Open start (auxiliary) switch.
7.
“P” to Blue (2-speed motor)
Closed
Open start switch 4 pole winding.
8.
“R” to Red
Open
Start auxiliary switch.
9.
“P” to Blue (2-speed motor)
3 Ohms
(approximate)
Refer to Blue to White and Violet to White.
10.
“P” to Blue (2-speed motor)
Closed
Open low (6 pole) winding run switch.