800793
49
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
i. When seal releases from lip of front panel, pull
out and remove the seal. Refer to Figure 15,
Step 4.
NOTE: The ease of installation of the loading door
seal can be improved using water or 409 lubricant to
work seal around circumference of loading door. Be
sure to orientate seal with the white arrow in the 12
o’clock position when installing the wire clamp ring
to front panel. Be careful not to overstretch tension
spring.
j. Remove two screws holding front panel to
washer cabinet.
k. Remove front panel (with loading door
attached) away from washer as far as wires
permit.
l. Remove two cabinet top hold down screws.
m. Remove three screws holding hood assembly to
control hood rear panel. Refer to Figure 5.
n. Pivot hood forward on cabinet top. Refer to
o. Disconnect hose from pressure switch and push
hose down through hole in cabinet top.
p. Disconnect wire harness at disconnect blocks,
power cord, motor harness wires and ground
wire from relay and control board.
q. Reinstall control hood assembly.
r. Lift front of cabinet top slightly and pull
forward to disengage from rear hold down
brackets.
s. Carefully lift cabinet top off washer and set
alongside the washer cabinet on protective
padding.
30. MIXING VALVE
a. Mixing valve is located on upper back right
corner of rear panel. Refer to Figure 17.
b. Shut off external hot and cold water supply and
remove two inlet hoses.
c. Loosen hose clamp and remove mixing valve-
to-dispenser hose at the mixing valve. Refer to
Figure 17.
d. Remove wire harness disconnect blocks from
mixing valve solenoid terminals. Refer to
Figure 17.
NOTE: Refer to wiring diagram when rewiring
solenoids.
e. Go to rear of washer and remove screw holding
mixing valve and plate to rear panel, then
remove valve and plate out through opening in
rear panel. Refer to Figure 17.
f. Remove screws holding valve to mixing valve
plate. Refer to Figure 17.