505033
73
Section 7 Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
CIRCUIT TO BE
TESTED
TIMER
No. 502964
TIMER
No. 502966
TIMER
No. 504547
TIMER
No. 504548
Timer Motor
L2 and T
L2 and T
N and T
N and T
Signal Control
–
P/B and P/B
–
P/B and P/B
Motor
L1 and M
L1 and M
L1 and M
L1 and M
Heat
L2 and H
L2 and H
L2 and H
L2 and H
Push-to-Start
M and S
M and S
M and S
M and S
Figure 47
MOD
60-1
XXX VAC
RSPCª
MODEL 275BEF
H
R
A
L2
L3
L2
S
L1
T
N
M
P/B
P/B
3 WATT
KI
NGSTON
No. 270
D327S
MOD
60-1
XXX VAC
RSPCª
MODEL 275BEF
H
T
L2
S
L1
N
M
P/B
P/B
3 WATT
KI
NGSTON
No. 270
D328S
TIMERS
502964
502966
504547
504548