Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
46. HEATER ASSEMBLY (Electric Models)
a. While supporting access panel, remove two
screws from bottom edge of access panel. Refer
to
.
b. Gently lower access panel to disengage locators
from bottom edge of front panel. Refer to
c. Remove two screws holding heater assembly to
heater box and remove heater assembly out
through front of dryer. Refer to
d. Disconnect wires from heater assembly. Refer
to
NOTE: When reassembling, be sure all wire
connectors are tight on element terminals, thermal
fuse and limit thermostat.
47. THERMOSTAT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to
.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to
c. Disconnect wires and remove thermostat
.
48. AIR DUCT
a. While supporting the access panel, remove two
screws from bottom edge of access panel. Refer
to
.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. Refer
to
.
c. Open loading door and remove screw from end
.
d. Lift lint filter out of air duct, paying close
attention to orientation.
Figure 22
Attaching
Screws
Seal
Thermostat
Ground
Screw
Wire
Harness
D400SE1F
Ground
Wire
Figure 23
D307SE1D
Front
Bulkhead
Front
Air Duct
Lint
Filter
Screw