14. TIMER DOES NOT ADVANCE IN AUTOMATIC CYCLE
POSSIBLE CAUSE
TO CORRECT
Inoperative cycling thermostat.
• Test thermostat and replace if inoperative.
Inoperative resistor (Electric Models).
• Test resistor and replace if inoperative.
Heater assembly does not heat or burner does not
ignite.
.
Heater assembly or burner cycles off prematurely.
.
Improper or inadequate exhaust system.
• Refer to
Installation Instructions
(supplied with dryer)
for exhaust requirements.
Drying large load.
• Timer will not advance until the load is almost dry.
Broken, loose or incorrect wiring.
• Refer to wiring diagram.
Timer motor is inoperative.
• Select a drying cycle and activate start switch.
• Rotate timer knob until signal sounds.
• Release timer knob.
• Signal should stop within ten minutes. If not, replace
timer.
Inoperative seals (air leaks).
• Check and replace any inoperative seals in the following
areas:
1. Seal between loading door and front panel.
2. Seal between front panel and front bulkhead.
3. Seal between blower cover and air duct.
4. Seal between cylinder and front or rear bulkhead.
5. Gap between air duct and filter mounting.
Summary of Contents for FES17AxF