512261
11
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
3. DRYER MOTOR RUNS BUT CYLINDER DOES NOT TURN
4. DRYER MOTOR DOES NOT STOP
POSSIBLE CAUSE
TO CORRECT
Motor drive pulley loose.
• Tighten pulley.
Belt not installed on pulley.
• Install belt. Refer to
Broken cylinder belt.
• Replace belt.
Clothes cylinder is binding.
• Check cylinder for binding and “out of round” condition.
• Check front and rear bulkheads for warping.
• Check cylinder rollers for binding.
• Check cylinder seals and glides for wear or damage.
Broken, weak or disconnected idler lever spring.
• Replace or reconnect spring. Refer to
.
Belt routed on wrong side of idler lever.
• Reroute belt. Refer to
Oil on cylinder.
• Wipe oil from cylinder.
Belt is “inside out.”
• Reinstall belt with ribbed surface against cylinder.
Idler lever is binding.
• Add grease between idler lever and motor mount.
• Replace idler lever and bolt, if needed.
Dryer is overloaded.
• Remove some laundry from dryer.
Wrong motor.
• Refer to parts manual for correct motor part number.
Wrong belt used on dryer.
• Check belt part number against correct part number in the
parts manual.
• Replace belt if needed.
Bent idler lever.
• Replace idler lever.
POSSIBLE CAUSE
TO CORRECT
Incorrect wiring to motor switch.
• Refer to wiring diagram.
Motor centrifugal switch sticky or plugged with
lint.
• Remove dust or lint and spray with a cleaner and lubricant.
Inoperative door switch.
• Test switch and replace if inoperative.
Inoperative timer.
• Test timer and replace if inoperative.