60
505872
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE: On models using unpainted, corrosion
resistant, coated steel cylinder, the cylinder must be
installed with the side marked “FRONT” or the
arrow pointing toward front of dryer.
l. Pull rear cylinder seal from under flanged edge
of bulkhead. Refer to Figure 33.
m. Carefully unhook spring from the seal strap.
IMPORTANT: The seal can be adhered to the
bulkhead using 3M-1300 Sealant (obtain locally).
This is accomplished by applying a bead of 3M-1300
Sealant around the entire flanged area where the
felt seal contacts the bulkhead. Strap must be
installed with cupped surface down against the seal
to hold the felt seal more firmly in place on the
bulkhead. Seal must be held securely under strap
and folded under flanged edge around entire
bulkhead.
Figure 35
DR049-SV-1
CYLINDER
ROLLERS
SEAL
STRAP
SPRING
BULKHEAD
ATTACHING
SCREWS
REAR BULKHEAD
MOUNTING BRACKET
TERMINAL BLOCK
BRACKET
OUTLET
COVER
REAR BULKHEAD
MOUNTING BRACKET
BULKHEAD
ATTACHING
SCREWS
HEATER BOX
HEAT
SHIELD
HEAT SHIELD
ATTACHING
SCREWS
OUTLET
COVER
SCREWS
SCREW