802643
21
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Dryer Troubleshooting
10. Dryer Heating Assembly Does Not Heat or Burner Does Not Ignite
(continued)
SWD1708S-b
Gas Models: Is
harness properly
connected to gas
controls?
Check
harness
connections
to gas valve
coils, sensor
and main
harness.
Reconnect as
required.
Test igniter
and replace if
inoperative.
Refer to
Dryer
Test
Procedures
section.
Gas Models:
Is igniter
inoperative?
Gas Models:
Is sensor
inoperative?
Test sensor
and replace if
inoperative.
Continued from
previous page.
Yes
No
Yes
No
Gas Models:
Is gas flow in
gas orifice
restricted?
Clean out gas
orifice.
Yes
Is cycling
thermostat
inoperative?
Test
thermostat
and replace if
inoperative.
Yes
Is wiring
broken, loose
or incorrect?
Refer to wiring
diagram.
Yes
Is timer
inoperative?
Test timer
and replace if
inoperative.
No
Yes
No
Gas Models:
Are gas valve
coils
inoperative?
Test coils and
replace if
inoperative.
Refer to
Dryer Test
Procedures
section.
Yes
No
No
Gas Models:
Is gas supply
insufficient?
Check gas
shut-off valve
in dryer and
main gas line
valve. Open
partially closed
gas shut-off
valve or
correct low
gas pressure.
Yes
No
No
Yes
Summary of Contents for CTSA7AWN