![Alliance Laundry Systems CHD25E2-CT025E Programming Manual Download Page 51](http://html1.mh-extra.com/html/alliance-laundry-systems/chd25e2-ct025e/chd25e2-ct025e_programming-manual_2901277051.webp)
Error Codes
Following is a list of possible error codes for an electronic con-
trol. Errors beginning with
EI
refer to external device Infra-red
communication errors. All other errors refer to machine errors.
Dis-
play
Description
Cause/Corrective Action
EI01
Transmission Failure
Communication failure. Re-aim external device and try again.
EI02
Device Time-out
Communication failure. Re-aim external device and try again.
EI03
Invalid Command Code
Incorrect machine type. Before downloading, ensure data is for current machine type.
EI05
Invalid or Out-of-Range Data
Incorrect machine type. Before downloading, ensure data is for current machine type
and values entered are within the minimum and maximum limits.
EI09
CRC-16 Error
Communication failure. Re-aim external device and try again.
EI0A
Framing Error
Communication error. Re-aim external device and try again.
EI0C
Time-out Exceeded
Communication error. Re-aim external device and try again.
EI0E
Encryption Error
Incorrect machine type. Before downloading, ensure data is for current machine type.
EI0F
Invalid Wake-up or Infra-red
Disabled
Communication failure or infra-red is disabled. Manually enable infra-red on control or
re-aim external device and try again.
ESH
Shorted Thermistor Error
Remove any lint build-up around thermistor. Inspect wires to the thermistor. If problem
persists, replace thermistor.
EoP
Open Thermistor Error
Remove any lint build-up around thermistor. Inspect wires to the thermistor. If problem
persists, replace thermistor.
E AF1
Airflow Switch Error (Switch
Fails to Open At End of Cycle)
Inspect lint screen and ductwork. Once error is cleared, control will go back to previous
mode of operation.
E AF2
Airflow Switch Error (Switch
Does Not Close After Cycle
Starts)
Inspect lint screen and ductwork. Cycle power to machine (power down, then power
up) or push Back keypad.
E AF
Airflow Switch Error (Switch
Bounces During Cycle)
Inspect lint screen and ductwork. Cycle power to machine (power down, then power
up) or push Back keypad.
E HEAt
Machine Did Not Reach Ex-
pected Temperature.
The ignition control has power, but a flame was not sensed after the programmed
amount of retries. Be sure that gas is turned on. If problem persists, troubleshoot the
ignition circuit. (Igniter, Cable, Ignition Control Module.)
E SL
Stove Limit 1 Error
Inspect tumble dryers venting/ventwork to ensure that the ventwork is adequate and that
there are no blockages. Be sure to clean and inspect lint screen. Remove any lint build-
up around the thermostat. If problem persists, replace thermostat.
E SL2
Stove Limit 2 Error
Inspect tumble dryers venting/ventwork to ensure that the ventwork is adequate and that
there are no blockages. Be sure to clean and inspect lint screen. Remove any lint build-
up around the thermostat. If problem persists, replace thermostat.
E CAb
Cabinet Limit Error
Remove any lint build-up around thermostat. If problem persists, replace control or
thermostat.
Table 11
continues...
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
51
Part No. 70444901ENR10
Summary of Contents for CHD25E2-CT025E
Page 2: ......