To Exit Production Test Cycle
The test will be exited when the time reaches
00
on the control in
the 10 Minute Test Cycle. Otherwise, the control must be pow-
ered down to end the test.
Production Test Cycle Quick Reference Table
Display
Test Mode
Comments
S HH
Software Version
HH
is the software version number.
Ct HHH
Control Type
2, 3, 4, 5 or 6, depending on brand.
PAd
Keypad Test
When a key is pressed, the control will display the number assigned to the keypad. As
each keypad is pressed, the control will display the number assigned to it in the last
digit of the display until the next key is pressed (example, if Key 1 is pressed the con-
trol will show
PAd 1
). When all keypads have been pressed, the control will advance
to next step after a one second delay.
doorOP
or
doorCL
Loading Door Test
The control will display the status of the loading door:
doorOP
if door is open or
doorCL
if door is closed.
LintOP
or
LintCL
Lint Door Test
The control will display the status of the lint door:
LintOP
if door is open or
LintCL
if door is closed. Loading door must be closed.
All LEDs and dis-
play segments will
light
Show Entire Dis-
play Mode
The audio signal is turned off. Control will stay in this mode until any key is pressed.
C HH
Machine Configu-
ration #2 Display
HH
is the configuration byte value. The control will remain in this mode until any key
is pressed.
-
DIP Switch Con-
figuration
The control will show the sum of all switches in the
On
position. The control will re-
main in this mode until any key is pressed.
Degrees in 5°F
[3°C] increments,
SH
,
oP
Thermistor Tem-
perature Test
The temperature will be displayed in either Fahrenheit or Celsius, depending on ma-
chine’s configuration (refer to
). If control senses a shorted ther-
mistor,
SH
will be displayed. If control senses an open thermistor,
OP
will be dis-
played.
-
Moisture Sensor 1
Test (Shorted)
. Test step lasts for 15 seconds.
-
Moisture Sensor 2
Test (Resistance)
. Test step lasts for 15 seconds.
nn SS
10 Minute Test
Cycle
Determines if tumble dryer can function in a cycle for 10 minutes. Start pad will flash
one second on and one second off. The Start pad can be used to decrease time remain-
ing. If Start pad is not pressed within 4.25 minutes, the control will return to Idle Mode.
Table 10
NOTE: If power to the control is turned off before 10 Mi-
nute Test Cycle has ended, the cycle will be cleared
from control.
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
48
Part No. 70444901ENR10
Summary of Contents for CHD25E2-CT025E