CE Approval
NOTE: Wire sizing listed in this table is based on Arti-
cle 310, Table 310.16 of the NEC; at 104°F [40°C] ambi-
ent temperature. Follow your local electrical codes.
Use only copper conductors, rated for 194ºF [90°C] or
higher, type THHN or better. No more than three current
carrying conductors per raceway. Contact your local
Authority having jurisdiction if you have questions. Cir-
cuit breakers should be UL 489 listed or better. Single
phase circuit breakers for single phase machines only;
three phase circuit breakers for all others.
NOTE: N and P Voltage - Where the protective conduc-
tor has a cross-sectional area of less than 10 mm2 Cu,
a second protective conductor of at least the same
cross-sectional area shall be provided up to a point
where the protective conductor has a cross-sectional
area not less than 10 mm2 Cu.
20 Models - CE Approval
Voltage Designation
Specifications
Code
V
oltage
Cycle
Phase
W
ire
Full Load Amps
Circuit Breaker
mm
2
F-Speed Models
B
120
60
1
2
8
10
2.5
W
200-240
50
1/3
2/3
4/3
6
2.5
Y
200-240
60
1/3
2/3
4/3
6
2.5
X
200-240
50-60
1/3
2/3
4/3
6
2.5
Q
Electric Heat 200-240
50-60
3
3
17- 20
25
2.5
P
Standard
380-415
50-60
3
3
2
6
2.5
Electric Heat
11
16
2.5
N
440-480
50-60
3
3
2
6
2.5
V-Speed Models
B
120
60
1
2
9
10
2.5
W
200-240
50
1/3
2/3
4
6
2.5
Y
200-240
60
1/3
2/3
4
6
2.5
X
200-240
50-60
1/3
2/3
4/3
6
2.5
Q
Electric Heat 200-240
50-60
3
3
17- 20
25
2.5
P
Standard
380-415
50-60
3
3
2
6
2.5
Electric Heat
11
16
2.5
N
440-480
50-60
3
3
2
6
2.5
Table 38
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
85