background image

Operation

15

70400401

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Rotation Sensor

The rotation sensor must “read” the key on the basket 
shaft or pulley. The sensor must be set approximately 
1/4 inch from the key or pulley. Look for the light on 
the sensor to come on as the key passes on the sensor; 
this is a correctly operating sensor. If no light appears, 
either the sensor is out of range or the key/pulley or the 
sensor is bad. In addition, if the light stays on 
continuously, then the sensor is too close to the 
component or the sensor is bad. 

Safety Tumble/Anti-Wrinkle

At the end of the cool down cycle, the tumbler will 
stop and display “END.” The DMP control will 
automatically rotate the basket for 5 seconds every 
2 minutes for a total of 20 minutes, until some 
function of the tumbler is activated/deactivated by the 
user. 

Operational Check for the Board Diagnostics

1. “dor” indicates that the loading or lint door is 

open.

2. Cycle the tumbler to check if the buzzer activates.

3. “P-F” indicates that the thermistor is short 

circuited or open circuited. 

4. “bbt” indicates a broken belt condition or a faulty 

rotation sensor. (Only available on tumblers with 
the rotation sensor.) 

5. Hold the START button to display the drum 

RPMs; the display will read “r##” where ## are 
the RPMs. (Only available on tumblers with the 
rotation sensor.) 

Ignition Control Operation

Power Up

After 24 VAC is applied to the ignition control pins 
24V and GND, the Diagnostic LED on the ignition 
control will turn orange/yellow. If a fault is detected 
the ignition control will enter Lockout Mode. If no 
faults are detected, the Diagnostic LED will turn 
Green and the ignition control will enter Standby 
Mode.

Standby Mode

While in Standby Mode, the ignition control will 
continually monitor the system for faults. Once 
24VAC

 

is applied to terminals TH and GND on the 

control, the ignition control will enter Start Up Mode.

Start Up Mode

During Start Up Mode, the ignition control will 
monitor the system for faults and begin the ignition 
sequence. If no faults are present, the ignition control 
will begin the ignition sequence by entering an 18 
second waiting period. During this time the Green 
LED on the ignition control will switch between Red 
and Green, before maintaining a Green color.

After the waiting period, the ignition control will turn 
on the igniter and gas valve. The igniter will remain on 
until a flame is sensed, or up to 10 seconds. 

Once a flame has been sensed the ignition control will 
stop sparking, the gas valve will remain on and 
ignition control will enter Run Mode.

If a flame is not sensed, the ignition control will then 
begin two additional retrials for ignition. The ignition 
control will re-enter the 18 seconds waiting period 
before the ignition control makes another attempt at 
ignition. If the three attempts at ignition fail, the 
ignition control will enter Lockout Mode.

Run Mode

While in Run Mode the ignition control leaves the gas 
valve on, monitors the flame signal, and leaves the 
igniter off. 

If a flame signal is lost during Run Mode, one 
additional retrial for ignition will take place within one 
second. The ignition control will restore the spark for 
approximately 10 seconds. If the ignition re-attempt 
fails, the ignition control will enter Lockout Mode.

The ignition control will remain in Run Mode until 
24VAC is removed from terminals TH and GND on 
the control. 

Summary of Contents for BA120L

Page 1: ...w comlaundry com Drying Tumblers 120 Pound Capacity 170 Pound Capacity Refer to Page 3 for Model Identification Part No 70400401R2 August 2007 Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine ...

Page 2: ......

Page 3: ...he room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the...

Page 4: ...s Introduction 3 Model Identification 3 Customer Service 3 Wiring Diagram 3 Serial Plate Location 4 Safety Information 5 Explanation of Safety Messages 5 Important Safety Instructions 6 Operation 8 Emergency Stop Button on CE Models 8 Operating Instructions 8 Control Instructions 9 Dual Digital Timer Control 9 Diagnostic Microprocessor Control 11 DMP OPL Models 12 Ignition Control Operation 15 Mai...

Page 5: ...920 748 3121 Wiring Diagram The wiring diagram is located in the junction or contactor box Models starting Serial No 0309____ or later will have the wiring diagram part number in the lower portion of the electrical data on the serial plate Gas Steam Thermal Oil 120 Pound BA120L BA120N BT120L BT120N BU120L BU120N CA120L CA120N CT120L CT120N CU120L CU120N IT120L IT120N BT120S BT120T BU120S BU120T CT...

Page 6: ...ial Plate Location When calling or writing for information about your product be sure to mention model and serial numbers Model and serial numbers are found on serial plate on rear of machine Refer to Figure 1 TMB1298N 1 Serial Plate Figure 1 TMB1298N 1 1 170 POUND TUMBLER 120 POUND TUMBLER ...

Page 7: ...gulations electrical wiring regulations and any other relevant statutory regulations Because of varied requirements applicable local codes should be thoroughly understood and all pre installation work arranged for accordingly NOTE The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be understood that c...

Page 8: ...ervice personnel 15 If not installed operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose you to substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer birth defects or other repro...

Page 9: ...ow the fabric care instructions supplied by the garment manufacturer 27 Never operate the tumbler with any guards and or panels removed 28 DO NOT operate the tumbler if it is smoking grinding has missing or broken parts 29 DO NOT bypass any safety devices 30 Solvent vapors from dry cleaning machines create acids when drawn through the heater of the drying unit These acids are corrosive to the tumb...

Page 10: ...laundry DO NOT OVERLOAD NOTE Overloading causes slow drying and wrinkling Close loading door Tumbler will not operate with the door open Step 3 Determine Control Type and Temperature Setting Refer to the various controls pages 9 15 follow instructions for the appropriate control type The type of fabric being dried will determine the temperature setting Consult the fabric care label or fabric manuf...

Page 11: ...t any time during the cycle OPEN DOOR If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed and the START button must be pressed in If the load cools to 90 F before cool down time expires the control will flash Lr load ready in the heat time display If the door is not opened the tumb...

Page 12: ...e to gas tumbler before servicing Close steam valve to steam tumbler before servicing Never start the tumbler with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the tumbler is properly grounded W002 WARNING Display Definition Corrective Action OP Open thermistor error Check thermistor Replace if inoperative Check ...

Page 13: ...ible alarm Reversing nonreversing selection Five user programmable programs RPM display when equipped with rotational sensor only Monitors the lint door switch operation Monitors the thermistor for operation The minimum drying time is 0 minutes and the minimum cooling time is 2 minutes The maximum drying or cooling time is 60 minutes The drying temperature may be set from 100ºF 38ºC to 185º 195ºF ...

Page 14: ... minutes per coin Coin only 6 Display Displays the drying time cooling time drying temperature and diagnostic codes 7 Program Select This button toggles through the five user programmable programs Holding this button will save a program as indicated in Programming 8 User Program LEDs Illumination shows which user program is currently being displayed 9 Display Select Toggles the display between the...

Page 15: ...d of cycle buzzer will remain on OFF indicates that the buzzer will sound for 5 seconds when the drying cycle is completed ON indicates that the buzzer will sound continuously until the STOP button is pressed or the loading door is opened 7 Safety Tumble Display Count or Pay If DIP switch 1 is set for OPL then DIP switch 7 in the ON position enables the safety tumble If DIP switch 1 is set for Coi...

Page 16: ...rrows to adjust the times and temperature 4 Toggle between reversing REV illuminated or nonreversing REV not illuminated Only for tumblers with the reversing option 5 To cancel this temporary programming mode push the STOP button once to stop the current cycle and once more to cancel the modified program settings The program will revert back to its original settings Reversing Operation 1 When the ...

Page 17: ...s are detected the Diagnostic LED will turn Green and the ignition control will enter Standby Mode Standby Mode While in Standby Mode the ignition control will continually monitor the system for faults Once 24VAC is applied to terminals TH and GND on the control the ignition control will enter Start Up Mode Start Up Mode During Start Up Mode the ignition control will monitor the system for faults ...

Page 18: ...age Detection If the voltage between terminals TH and GND on the control is below 18 75VAC 0 75VAC for more than 3 seconds the ignition control will turn off the gas valve and will not attempt to spark The Diagnostic LED will display Error Code 5 The ignition control will not enter Lockout Mode if a low voltage condition is detected but will enter Standby Mode and wait for the low voltage conditio...

Page 19: ...and one half second off Error codes are separated by a one second pause before the code is repeated LED Color Description Orange Yellow Initialization Green Standby Normal Operation Red Fault Indication Code Table 3 Error Code DGN LED status Fault Type 1 Red Ignition Control Internal Failure 2 2 Red Flashes Gas Valve Not Connected 3 3 Red Flashes Ignition Flame Sense Failure 4 4 Red Flashes Reset ...

Page 20: ...es so Excessive gaps between the lint screen and the lint screen panel allow lint to pass into the ductwork system e Carefully wipe any accumulated lint off of the cabinet high limit thermostat and thermistor Failure to do so will allow a buildup of lint in this area to act as an insulator causing the tumbler to overheat Refer to Figure 7 f Replace the lint compartment panel on the tumbler ensurin...

Page 21: ... motors 2 Use a vacuum to clean lint from rear limit thermostat cover 3 Check and clean steam coils if applicable 4 Check flow of combustion and ventilation air 5 Check belt tension and condition Replace worn or cracked belts Bi Annually 1 Check mounting hardware for any loose nuts bolts or screws 2 Check gas connections for leakage 3 Check for loose electrical connections 4 Check steam connection...

Page 22: ...nding tumblers remove all combustible materials including lint before operating the machine Check cylinder for foreign objects to avoid damage to clothing and equipment Clean lint from lint compartment and screen to maintain proper airflow and avoid overheating Remove lint and debris from inside exhaust duct to maintain proper airflow and avoid overheating Ensure even lint distribution over lint s...

Page 23: ...vicing Close gas shut off valve to gas tumbler before servicing Close steam valve to steam tumbler before servicing Never start the tumbler with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the tumbler is properly grounded W002 Check mounting hardware for any loose nuts bolts or screws Check gas connections for l...

Page 24: ...Clothes Not Dry Possible Reason Corrective Actions Insert correct coin s or valid card if applicable Close the loading door tightly Close lint panel tightly Press the PUSH TO START or START pad button Be sure power cord is plugged all the way into the electrical outlet Drying timer is in OFF position Check the main fuse and circuit breaker Check fuses located in the machine Insufficient airflow Ga...