M413487
53
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
72. DRIVE BELT TENSION
NOTE: If cylinder belts will be adjusted, service
them before drive belt.
NOTE: To find the proper tension, apply light
thumb pressure midway between the sheave and
motor pulley, and adjust until the belt can be
depressed approximately 1/2 inch (13 mm).
a. Support corner drive guard and remove screws
holding corner guard to rear of tumbler.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler.
c. Reinstall drive guard.
d. Loosen the two side bracket attaching screws.
e. Turn the adjusting nuts clockwise until proper
tension is reached.
f. Tighten all nuts and screws.
Figure 28
T237PE3C
SIDE
BRACKET
ATTACHING
SCREW
SIDE
BRACKET
MOTOR
MOUNTING
BRACKET
ADJUSTING
TUBE
ADJUSTING
NUTS