Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37. STOVE HIGH LIMIT THERMOSTAT
(Gas Models)
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove screws holding thermostat cover to
stove.
d. Remove thermostat cover. Refer to Figure 9.
e. Disconnect wires to thermostat.
f. Remove the two thermostat attaching screws.
g. Remove thermostat.
38. CABINET HIGH LIMIT THERMOSTAT /
LOAD READY THERMOSTAT
(Located on rear of tumbler near fan)
a. Support corner drive guard and remove screws
holding corner drive to rear of tumbler. Refer to
Figure 13.
b. Support drive guard cover and remove screws
holding guard to rear of tumbler. Refer to
Figure 13.
c. Disconnect wires from thermostat. Refer to
d. Remove two screws holding thermostat to rear
of tumbler.
Figure 10
T209SE1B
LOAD READY
THERMOSTAT
SCREW
WIRE
CABINET
HIGH LIMIT
THERMOSTAT