M413487
31
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
31. FUSE HOLDER
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove control box cover. Refer to Figure 2.
d. Disconnect fuse holder wires.
e. Unscrew fuse holder nut from side of control
f. Pull fuse holder out of control housing.
32. SIGNAL BUZZER
a. Remove four screws holding access panel to
cabinet. Refer to Figure 1.
b. Lift access panel off top edge of front panel and
pull panel forward. Refer to Figure 1.
c. Remove control box cover. Refer to Figure 2.
d. Disconnect buzzer wires.
e. Remove screws holding buzzer to housing.